Will grasp the refrigerant emergency measures

1, avoid getting into high concentration of water vapor.

Although some refrigerants under the condition of normal temperature and pressure is not easy to burn, but under the condition of high pressure and high concentrations of air, the mixture can burn or even an explosion.

2, refrigerant storage should be away from fire and high temperature of the surface of the metal.

3, refrigerants with low toxicity, high doses of inhaled refrigerant (

Such as: R407C)

Will lead to anesthesia, very high concentration will lead to abnormal heart rhythm and lead to sudden death.

If the concentration of R407C and everything in the closed space high will lead to lack of oxygen asphyxiation.

4, eyes, hands and skin contact with the refrigerant will cause frostbite, need contact please wear freeze protection gloves.

5, with the air mixed gas shall not be used for pressure and leak test.

6, don't make contain refrigerant liquid heating, heating decomposition will produce a strong toxicity and (

R407C strong corrosive)

(

Everything excitant)

The steam;

If the overheating, receiver will explode.

7, do not hit or abuse of refrigerants.

8 and refrigerant cylinder must be vertically.

9, using a suitable wrench open and close of refrigerant valve door.

2 refrigerant leakage and emergency handling refrigerant leakage, come up to a lot of smoke, leak from the surrounding environment has a strong irritating smell;

The leak of the equipment, pipeline chills, severe frozen. 

 A, homework personnel protective measures, protective equipment and emergency disposal procedures: 1)

Delimit warning zone, according to the influence of the gas area, irrelevant personnel from the lateral wind, the wind to evacuate to the safe zone.

2)

, for security, should be far away from the leak location.

3)

, advice, emergency treatment personnel Dai Zheng pressure self-contained breathing apparatus, in general work overalls.

Prohibit contact or across the leakage.

4)

As much as possible, to cut off the leak source.

Spray water inhibition of steam or a change in steam flow of cloud, avoid the leakage water contact.

5)

A direct hit, ban water leakage or leakage source.

Second, the environmental protection measures: 1, cut off the leak source as possible.

 If ventilation is good, can make a small amount of spill evaporation.

If a large amount of overflow, ventilate area, and sand or other appropriate absorption materials cover on it.

2)

And prevent liquid from entering the drainage pipe, sewage, basement or working in the pit, to prevent the gas through the sewers, ventilation system and spatial diffusion in sealing.

Because the steam will cause choking.

3)

Leakage, leakage gas allows discharged into the atmosphere, place keep ventilated 4)

, in the event of combustion, the use of fire extinguishing media.

To the refrigerant tank water, make its cooling;

Or use extinguishing equipment.

3 emergency relief measures 1, inhaling low concentration inhaled can irritate the mucous membrane, high concentration of R407C atmosphere will result in anesthesia, including loss of consciousness.

High suction will lead to abnormal heart rate and sudden death.

Acute poisoning: mild performance for the skin, mucous membrane of stimulus-response, rhinitis, laryngitis, bronchitis;

There may be cornea and skin burns.

Followed by laryngeal edema, glottis narrow respiratory tract mucous membrane cell falls off, airway obstruction and suffocation, can have toxic pulmonary edema and liver damage.

Disposal method: if accidentally inhaled, should put the injured away from the high concentration, in the warm area.

If there is need for oxygen.

If breathing stops or weak gradually, should undertake artificial respiration, and heal nearby.

2, skin to skin contact splashes of liquid can cause frostbite.

 If the frostbite: 1, keep of soaking in double temperature in 38 to 42 ℃ warm water.

2, don't rub.

Do not use hot water or radiant heat.

3, change contaminated clothing.

4, the use of clean, dry dressing dress, go to a doctor.

Warning: after frostbite, clothes may be pasted into the skin.

3, with eyes splashes of liquid can cause frostbite, crystal turbidity, corneal perforation, and even blindness.

If not careful eyes, should be used immediately wash eyedrops or clean water to rinse, at least 15 minutes may not close their eyes.

Go to a doctor immediately.

4, eat this kind of situation is unlikely to -

But once occurred, will lead to frostbite.

Do not force vomiting.

If the injured have consciousness, should use clear water to clean mouth, and make them drink 200 - up

300 ml of water.

Immediately go to a doctor, medical treatment and further medical support.

For R407C, due to the arm will lead to heart disease, should avoid to use adrenaline and similar kind of sympathetic nerve medicine.
Hangzhou E cool refrigeration Co.,Ltd who is highly knowledgeable about manufacturing as well as selling and confident in our ability to create finest products as air conditioner capacitor start capacitor suppliers.
We would like to offer our comprehensive service to our customers who interested in refrigerant gas.
Hangzhou E cool refrigeration Co.,Ltd offers the best for indoor as well as outdoor use. To find your ideal at attractive offers, visit us at Arkool Refrigeration.
Hangzhou E cool refrigeration Co.,Ltd is a team of manufacturers who have 10+ year experience on creating business plans and other types of productions with top-tier management firms and various multinational corporates.
On top of making sure all our day-to-day operations are running smoothly, Hangzhou E cool refrigeration Co.,Ltd needs to ensure that we're keeping up with all the quality standards of air conditioner capacitor.                                

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect