loading

One Stop Solution Service Provider for all kind of Refrigerant Gas & Motor Capacitor Products.

Will change as refrigerant R22 and R134a has a comprehensive analysis: the road to the future

refrigerant is also called the refrigerating agent, commonly known as snow in some areas of the south. It is a cycle in the refrigeration system and through its own change of state in order to realize the

refrigeration work material. Refrigerant in the evaporator absorbed by the cooling medium ( With air or water, etc. ) Heat and vaporization, heat transfer in the condenser to

ambient air or water and condensation, environmental problems are attention by more and more people now, in some parts of the government also issued a blanket ban fluorine policy laws,

but the fluorine is not only the concept of error, and lead to the application of the broad masses of users and manufacturers. This article from the concept of freon, international convention, national policy,

application of commonly used features of refrigerant R22 and R134a has a comprehensive analysis. A, the concept of freon

freon is saturated hydrocarbons ( Hydrocarbons) The floorboard of the halogen derivative. At present, the domestic many users are required to produce use the environmental protection such as everything

refrigerant, the reason is that respond to a nation called on to protect the environment. Actually freon R22 and R134a has a family member, as part of the hydrogen CFCS. From freon

you can see, the definition of it is now the so-called green refrigerant everything, r410a and R407C actually belong to the family of freon. So the forbidden fluorine

this concept confuse the ban should not be banned content.

freon is able to destroy ozone because CL elements contained in the refrigerant, and with the increase of CL atom number of ozone depletion ability

will increase, with the increase of H element content of ozone depletion ability; The greenhouse effect is mainly due to the refrigerant in the process of slow oxidation decomposition,

generate large amounts of greenhouse gases, such as CO2, etc.

according to the different molecular structure, freon refrigerant can be roughly divided into the following three categories: 1. CFCS classes: referred to as 'CFC, mainly including the R11, R12, R113,

? , R115, R500, R114,

because of its effect on the destruction of the ozone layer *, has been the Montreal protocol as a kind of controlled substances. This kind of material has been gradually to ban the use of our country.

2。 Hydrogen CFCS: as for short, mainly including R22,

R123, R141b and R142b, ozone depletion coefficient is only a few percent of R11, therefore, the China national plan to phase out the ozone-layer-depleting substances

will be as kind of substance as CFC class * important transitional alternative material.

3。 Hydrogen fluoride hydrocarbons, referred to as 'HFC, mainly includes everything, R125, R32, R407C, R410A, R152, ozone depletion coefficient is 0,

but warming ozeme depletion potential is higher.

all refrigerants used in our country at present, Including environmental refrigerant) All are freon products, ideal of freon refrigerant so far

has not been developed. Before the new refrigerant developed, we have to solve is air conditioning unit to choose that kind of refrigerant, for our survival

environmental damage caused by relatively small.

3, the application of R22 and R134a has a characteristic difference

it is very hard to choose an appropriate refrigerant replacement, must consider many factors and comprehensive evaluation, and should not only conform to the ozone-depleting ozeme depletion potential ( ODP) ,

the global warming ozeme depletion potential ( GWP) Requirements, at the same time should also consider the thermal properties, toxicity, flammability, compatibility, investment and operation cost, etc.

below to the application of R22 and R134a has a characteristic analysis is as follows 1, R134a has a global warming ozeme depletion potential ( GWP) To zero. 25, R22 is 0. 36, both belong to the greenhouse gases. 2, everything of ozone-depleting ozeme depletion potential ( ODP) 0, R22 is 0. 6, this is the reason for everything become environmentally friendly refrigerants.

3, R134a has a specific volume is 1 of R22. 47 times, and the latent heat of evaporation is small, so everything refrigerating capacity of the unit is only 60% of R22 unit.

press unit refrigerating capacity price computation, R22 unit price about everything about 60% of the unit.

4, R134a has a thermal conductivity than R22 fell by 10%, so everything of the unit heat exchanger heat transfer area need to be more big. 5, R134a has a strong water imbibition, 20 times that of R22, so greater demands of the dryer in the unit system, to avoid ice blocking phenomenon.

6, everything is larger than that of R22 in rubber material swelling effect is stronger, in actual operation and mid-cooling medium leakage rate is higher. In addition to copper corrosion resistance is stronger,

will happen in the process of using 'copper plating phenomenon', so must add additive in the system.

These refrigerant gas start capacitor suppliers are meant to serve as a guide for business owners on how to both identify potential opportunities for transformative innovation and how to adapt to the constantly changing technologies of today.

If you are thinking of having a , then you must be first clear about the purpose, which is driving you to buy this device. Hangzhou E cool refrigeration Co.,Ltd offer quality for your needs with complete assurance of ability to serve your purpose.

On top of making sure all our day-to-day operations are running smoothly, Hangzhou E cool refrigeration Co.,Ltd needs to ensure that we're keeping up with all the quality standards of air conditioner capacitor.

Hangzhou E cool refrigeration Co.,Ltd are providing this to you at very low cost. Our claims are only based on different feed-backs received from various clients and not based on self-judgment.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect