Why do Gree inverter air conditioners need to add refrigerant and how to add it?

Winter is coming to an end, the weather will be getting hotter and hotter, the air conditioners have also become busy, and the idle air conditioners have also begun to prepare for work. If the air conditioners do not cool down, there are usually two reasons. One is, There are many gray layers (this is to be cleaned regularly), and the second is fluorine leakage. If you need to add refrigerant, you can solve the problem of adding in a few easy steps. Refrigerant is our name for air-conditioning refrigerants. In fact, it should be said that it is Fluorine, the air conditioner needs a refrigerant to be cooled. When the air conditioner is not cooling, you should ask a professional to help you repair it or check it. It is not recommended that the non-professional handle it by yourself. Label the amount of increase, like how much refrigerant and how much fluorine is added. This won’t be possible, you can let a professional teach you once, and it will be the next time.

Gree inverter air conditioner adding refrigerant-method

First, turn on the air conditioner and set it to refrigeration. Then the external machine will be in a normal working state (turn on The indoor unit panel, remove the filter, and found that part of the evaporator has condensation or frost. In fact, it is due to insufficient refrigerant); open the small nut of the triangle valve between the outdoor unit and the connecting pipe (not the one with the hexagonal screw hole next to it) , There is a hexagonal screw on the side of the big and small pipes, which are used to harvest the refrigerant when the air conditioner is moved. It is not usually used); connect with the refrigerant pipe (use a fluorine-filled hose to connect the refrigerant cylinder, repair Meter and fluorine filling port to remove the air in the hose); the pressure to start the refrigerant is about 4.5-5.5MPa. After adding, screw on the nut and cover it.

Usually there is a hexagon socket screw on the side of the big and small pipes, which is used to harvest the refrigerant when the air conditioner is moved. Usually, you don’t need to twist the two hexagon sockets when you add refrigerant. For the screw, there are a few hexagonal screws that need to be screwed in the large tube (provided that the manufacturer does not have an air conditioner with a thimble in the maintenance port, and it needs to be screwed. When this type of air conditioner is encountered, the refrigerant connection tube is connected, and then the large tube You can add refrigerant by twisting the hexagonal screw one or two turns inside. The small tube does not move. After adding, you must screw it back to the original position before removing the refrigerant connecting tube.

Today I introduced you how to add refrigerant. Do you understand? Refrigerant is the element to ensure the refrigeration of the air conditioner. Generally, the air conditioner will not lack fluorine within a few years. If there is a lack of fluorine, it may be considered whether the machine is leaking. You need to call the after-sales staff to operate it. If you are not sure about it, do not add fluoride yourself to avoid potential safety hazards. In addition, it may cause excessive fluoride and cause damage to the machine.

is frequently used by people in daily life since it can improve start capacitor suppliers and start capacitor suppliers.

Are you looking for ? Hangzhou E cool refrigeration Co.,Ltd has the collection you want, like start capacitor suppliers or start capacitor suppliers and many more in the online stores. Visit Arkool Refrigeration to know more.

refrigerant gas has a very good repute over the global market.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect