Why air conditioning dripping, and find out what reason is caused by _

Many consumers reflect, home air conditioning appear slack phenomenon. Doubt is the product quality problems or where I went wrong? Together let's have a look at the knowledge of the air conditioning is leaking. Air conditioning is leaking want to know why is leaking, you first need to understand the working principle of air conditioning. Air conditioning compressor to compress refrigerant, through valve so that it has expanded to release heat, the temperature of the refrigerant was reduced. Then the refrigerant into the indoor evaporator, through the evaporator contact with indoor air to absorb heat in indoor air, compresses it again and again, such reciprocating cycle, a little heat away the indoor air. And the water vapor in the air in case of low temperature of the evaporator will turn into water, which goes a long way to explaining the reason of the air conditioning dripping. Let's have a look at the concrete reason and solution: air conditioning dripping air conditioning is leaking reason one: indoor machine migration to insecure indoor parts installation shift occurs, indoor machine fixed hangs Taiwan fixed installation is firm, shifting in the long run, lead to a drain raises a side position on the high side, causing drainage difficulty; Indoor machine body level improper installation, indoor machine horizontal installation tilt, pipe crossing direction position excessively high dew outside. Solution: move the air conditioner, with normal liquid level realign the position of air conditioning, balancing or try to lower air conditioner condensate pipe mouth side. Air conditioning is leaking reason two: dew on piping due to the poor quality of the heat preservation material on the pipeline or too thin, or did not completely package, when the refrigerant inside through cause condensation. Solution: this is our common indoor piping dripping phenomenon, this phenomenon occurs, the first thing we should disassemble the tape check insulation aging or installation is in order, such as find gaps or slants thin, can again the parcel. Can replace the aging tape at the same time maintain a copper tube of air conditioning in sealing leakage reason 3: a drain drainage bad or the drain is blocked due to aging relaxation or bend into the wave shape, poor drainage also easy to cause air conditioning dripping phenomenon. Second, lead to outdoor drainage pipe is blocked or drain plug is stolen goods, cause dew can't discharge. Or the drain plug was stolen goods, cause dew can't discharge. Solution: if a drain aging or relaxation need to change a drain, if is clean up dirt block as long as can. Air conditioning is leaking reason 4: heat exchanger drop of heat exchanger is too dirty can cause air conditioning impeded drainage, by this time the indoor machine blade will gather a lot of water and drip. Or was caused by a lack of air conditioning refrigerant heat exchanger uneven temperature, also can produce dripping phenomenon. Solution: clean the heat exchanger, can use commercial detergent washing, brush with wool brush gently, also can use high-power electric hair dryer cold wind blow to dust. Of course, if is a problem of refrigerant ( Through the pressure gauge can be measured) , can only ask professional add refrigerant. The cause of the air conditioning water and solution - Air conditioning separate-bodied air-conditioners drip reason: compressor at work, can produce cold work, while the refrigerant by compression produced cold work, put cold work to leak, so the transmission of cold refrigerant pipe and condenser surface temperature is extremely low. Saturated water vapor in the atmosphere, the water has the property of cooling, liquefy into water, so there is outside the machine 'drip' phenomenon, solution: machine outside water belongs to the normal phenomenon, can be a drain connection pipes can solve this problem, you can also use water container will be collected, used to water the flowers and sweep the floor, etc.

We are a performance driven culture that uses air conditioner capacitor to ensure continuous improvement.

Dedicated to bringing you professional refrigerant gas solutions and related products – from start capacitor suppliers to start capacitor suppliers, Hangzhou E cool refrigeration Co.,Ltd is your air conditioner capacitor helper. Visit us at Arkool Refrigeration.

Hangzhou E cool refrigeration Co.,Ltd's core technology of refrigerant gas enables us to understand and utilize in a right way.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect