loading

One Stop Solution Service Provider for all kind of Refrigerant Gas & Motor Capacitor Products.

What is the air conditioning refrigerant? The working principle of air conditioning refrigerant

When the cooling effect of air conditioner is not good, sometimes it is caused by insufficient air conditioner refrigerant, and air conditioner refrigerant needs to be added. So what is the air conditioning refrigerant? What is the working principle of air conditioning refrigerant? In this issue, the editor will introduce air-conditioning refrigerants and their working principles. Refrigerant, also known as refrigeration working fluid, is the working medium of the refrigeration cycle. It uses the phase change of the refrigerant to transfer heat, that is, the refrigerant absorbs heat when it vaporizes in the evaporator and releases heat when it condenses in the condenser.

1. Operating principle

When the air conditioner is in refrigeration operation, the low-temperature and low-pressure refrigerant gas is sucked in by the compressor and then pressurized to become high-temperature and high-pressure Refrigerant gas, high-temperature and high-pressure refrigerant gas passes through the condenser (generally air-cooled, that is, the heat dissipation copper pipe of the outdoor unit) radiates heat in the outdoor heat exchanger, and becomes a medium-temperature and high-pressure liquid (the heat passes through the outdoor circulating air Go), the medium-temperature and high-pressure liquid becomes low-temperature and low-pressure liquid after capillary expansion and pressure reduction. The low-temperature and low-pressure liquid refrigerant passes through the evaporator (indoor unit copper pipe) to absorb heat and evaporates and becomes a low-temperature and low-pressure gas (indoor air passes through The surface of the heat exchanger is cooled down to achieve the purpose of lowering the indoor temperature), and the low-temperature and low-pressure refrigerant gas is sucked in by the compressor, and so on. Air-conditioning refrigerants Air-conditioning refrigerants In general, air-conditioning refrigerants in the air-conditioning system are a cycle of compression-condensation-expansion-evaporation.

Two. Addition method

Under normal temperature and pressure, R410A is a non-azeotropic mixture of fluoroalkane without chlorine. The color gas is stored in a steel cylinder. Combining the characteristics of R410a[1], the application practice of using R410a to replace HCFC22 in a certain room air conditioner system was carried out, and the theoretical analysis and system matching were carried out. The experimental results show that under the same conditions Compared with HCFC22, the heat transfer coefficient is improved and the flow resistance is reduced. After the system is optimized and matched, the performance (COP) is greatly improved, reaching the A-level energy efficiency level in the European market.

Generally, we may use low pressure refilling and static refilling.

1. The air conditioner is turned on for refrigeration and then weeping from the low pressure. When added to 0.35~0.55Mpa is enough, and then observe the cooling effect of the air conditioner. If possible, the measured high pressure cannot exceed 2.2Mpa.

2. When the air conditioner is disabled, add fluoride from the fluoride point. It is appropriate when the system pressure reaches 0.8~0.9Mpa

3. Let the air conditioner run for 30 minutes and do a careful inspection.

4. The correct method of refilling is to take your time when refilling. After adding a little bit, let the air conditioner run for about 10 minutes, and then measure the pressure and current. The pressure and current are used as the standard. In that case, it may have been increased. When adding fluoride in winter, the four-way valve coil can be disconnected, or the indoor temperature sensor can be artificially brought to a temperature that can be cooled. Sometimes the air conditioner can also be operated in dehumidification mode, which does not require very high temperature.

start capacitor suppliers air conditioner capacitor processes have been widely used to produce start capacitor suppliers such as start capacitor suppliers, start capacitor suppliers, and start capacitor suppliers etc.

The Global refrigerant gas Leader. Hangzhou E cool refrigeration Co.,Ltd will build a unique portfolio of Arkool and related brands, striving to surpass our competitors in quality, innovation and value, and elevating our image to become the air conditioner capacitor company most customer turn to worldwide.

To offer abundant options of product is an important factor to a company, such as refrigerant gasstart capacitor suppliers to afford high-quality products for customers.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  CHEMLONG CO.,LIMITED / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect