What are the common methods for refrigerant leak detection

  【】Visual inspection of leaks

   When oil traces are found somewhere in the system, this may be a leakage point.

   Visual leak detection is simple and easy, no cost, but it has big defects. Unless the system suddenly breaks and the system leaks a large leak point, and the system leaks liquid colored media, the visual leak detection cannot be located.

   soapy water leak detection

   fill the system with 10-20kg/cm2 pressure nitrogen, and then apply soapy water to each part of the system. The bubbling point is the leakage point. This method is currently a common leak detection method in roadside repair shops z*, but people’s arms are limited, and people’s eyesight is limited, and in many cases no leaks can be seen at all.

  Nitrogen water leak detection

   Fill the system with 10-20kg/cm2 pressure nitrogen, immerse the system in water, the bubbling point is the leakage point. This method is essentially the same as the previous soapy water leak detection method. Although the cost is low, it has obvious shortcomings: the water used for leak detection is easy to enter the system, causing the materials in the system to be corroded, and the high-pressure gas may also cause damage to the system. Large damages and labor intensity during leak detection are also high, which increases the cost of maintenance and repair.

   Halogen lamp leak detection

   Ignite the leak detection lamp and hold the air tube on the halogen lamp. When the nozzle is close to the system leakage, the flame color changes to purple blue, that is Indicates that there is a large number of leaks here. In this way, open flames are generated, which is not only dangerous, but the combination of open flames and refrigerants will produce harmful gases, and it is also difficult to accurately locate leaks. So almost no one uses this method now. If you can see it, it may be in the stage of non-civilized society.

  Gas differential pressure leak detection

  Using the pressure difference inside and outside the system, the pressure difference is amplified by the sensor, and the leak detection result is expressed in digital, sound or electronic signals. This method can only qualitatively know whether the system is leaking and cannot accurately find the leak point.

As we have known for quite some time, the success of Arkool in the future will depend greatly on our ability to strike a balance between valuable human insight and interaction with technology.

Our vision serves as the framework for our air conditioner capacitor and guides every aspect of our business by describing what we need to accomplish in order to continue achieving sustainable, quality growth.

Hangzhou E cool refrigeration Co.,Ltd provides professional , technology and human expertise clients need to find trusted answers. Go to Arkool Refrigeration for answers.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect