Three ways to determine whether cold water machine need to add refrigerant

Many users in the process of using cold water machine, will find enough cold, cold water machine the beginning can run cool after a period of time found that the drop in temperature, small make up today by three methods to distinguish the refrigerant is insufficient, and then look for other reasons. A, current method: using clip-on ammeter monitoring the working current outdoor ( Including the compressor and the fan current) , if the current value in line with nameplate nominal rated current, shows refrigerant appropriate; If is lower than the rating too much, the refrigerant is too little, should be added. Gage pressure method: refrigeration system low voltage side pressure level is related to how much refrigerant. Beijing refrigerant manufacturer hint at low pressure valve connected to pressure gauge, refrigeration and air conditioning switched on at the beginning of the gage pressure drops, run more than 10 minutes, if the gage pressure steady at 0. About 49 mpa as normal. Three, observational method: to observe the near near the high pressure valve outdoor high pressure pipe and low pressure valve of low pressure pipe condensation. Beijing refrigerant manufacturer suggest general condensation pressure tube, and cold, if the low pressure tube and condensation, have cold feeling, about 3 ℃ temperature is higher than high pressure pipe, refrigerant suitable. If the low pressure pipe condensation, have warm feeling, then refrigeration dose is not enough, need to add; If condensation of low pressure pipe, or compressor start 1 minute or so every time, low pressure pipe frost, after again into dew, explain too much refrigerant, to put off some. The above three methods to measure current and observe high pressure, low pressure pipe condensation situation is given priority to, combination table method, to determine whether to add refrigerant. Beijing refrigerant manufacturer suggest it is important to note that the air conditioning refrigeration, outdoor fan must be open, otherwise the evaporator air around failing to disperse, decreased evaporation temperature, evaporation pressure drop, read the table of small pressure, current is small, the wrong result.

Hangzhou E cool refrigeration Co.,Ltd specializes in undertaking corporate offers to cater the needs of different companies.

Hangzhou E cool refrigeration Co.,Ltd are a market-focused, process-centered organization that develops and delivers innovative solutions to our customers, consistently outperforms our peers, produces predictable earnings for our customers, and provides a dynamic and challenging environment for our employees.

start capacitor suppliers refrigerant gas are used largely for start capacitor suppliers such as start capacitor suppliers.

Our company is professional in manufacturing air conditioner capacitor especially start capacitor suppliers.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect