The working principle of the air conditioning refrigerant

when the air conditioning refrigeration result is bad, sometimes is because of lack of air conditioning refrigerant, need to add air conditioning refrigerant. So what is the air conditioning refrigerant? What is the working principle of air conditioning refrigerant? This small make up to introduce air conditioning refrigerant and its working principle.

refrigerant is also called the refrigerating agent, is the working medium of refrigeration cycle, the use of phase change of the refrigerant to transfer heat, both the refrigerant in the evaporator vaporization heat absorption, condensed in the condenser heat release.

a works

in refrigeration air conditioning runs, after low temperature low pressure refrigerant gas is the compressor suction pressure into the high temperature and high pressure gas refrigerants, refrigerant of high temperature and high pressure gas passes through the condenser ( General air conditioning is air cooled, namely the cooling tubes outdoor) Heat release in the outdoor heat exchanger, become a medium temperature high pressure liquid ( Heat away by circulating air outdoor) , and medium temperature high pressure liquid into the low temperature low pressure liquid after capillary expansion depressurization, pass through the low temperature low pressure liquid refrigerant evaporator ( Indoor machine of brass) Heat evaporates into low temperature low pressure gas ( Indoor air through the heat exchanger surface is cooling, achieve the purpose of make indoor temperature drops) , and the low temperature low pressure refrigerant gas in the compressor, so cycle. Air conditioning refrigerant air conditioning refrigerant in general, air conditioning refrigerants in air conditioning system is a compression - - Condensation - - Inflation - - A cycle of evaporation.

add method

under atmospheric pressure, r410a is a chlorine fluoroalkane non azeotropic mixed refrigerant, colorless gas, storage in the cylinder. In combination with R410a [ 1] Features, to a certain type of room air conditioner system by using R410a alternative HCFC22 application practice, the theoretical analysis and system matching. The experimental results show that, under the same conditions, relative to the HCFC22, improve the heat transfer coefficient, flow resistance drop, through the system optimization matching design, performance ( 警察) Increased sharply, to achieve A grade level of energy efficiency in European market.

usually we may be using low pressure filling and static injectors. From the low voltage refrigeration and air-conditioning with tears, when added to 0. 35 ~ 0. 55 mpa can, to observe the air-conditioning refrigeration effect. If you can, high pressure no more than 2. 2Mpa。 When air conditioning stopped, from the add fluoride fluorine. When the system pressure reaches 0. 8 to 0. Run to let air conditioning refrigeration 30 minutes, do careful inspection.

4。 When filling the right way, the filling must take your time, add a little let air conditioning running after 10 minutes, and then test the pressure and current, unavoidably again by several times, not to as standard pressure and current at the time, in that case, may have been added. When winter to add fluoride, can disconnect the four-way valve coil, can also make indoor thermal head to open refrigeration can refrigeration temperature is reached. Sometimes also can let air conditioning in the dehumidification mode, it is not very tall to the requirement of temperature.

Hangzhou E cool refrigeration Co.,Ltd are maintaining a consistent bottom-line profit and that you've shown steady growth over the past few years.

Hangzhou E cool refrigeration Co.,Ltd provides which will help you start capacitor suppliers in a durable and reliable way. To learn more, go to Arkool Refrigeration.

refrigerant gas is one of the best products sold in the market today.

Hangzhou E cool refrigeration Co.,Ltd's core technology of air conditioner capacitor enables us to understand and utilize in a right way.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect