The use of the refrigerant

1, refrigerant selection requirements 1. 1, the working temperature and working pressure refrigerant wants moderate under atmospheric pressure, the refrigerant evaporation temperature is low enough, with snow kind of meet the requirements of the temperature of the cooling; At room temperature, the refrigerant should have lower condensing pressure, because the condensing pressure too high sealing performance of the refrigeration system agent structure strength requirement is high. General requirements of the refrigerant condensing pressure is: 12 x 105 ~ 15 x 105 Pa; At room temperature, the refrigerant evaporation pressure have higher disposable cylinders, because if the pressure inside the evaporator is lower than the atmospheric pressure, the air easily through the gap into the refrigeration system of the outside world, make the pressure in the system, reduce the refrigerating capacity, increase power consumption. At the same time the refrigerants in air moisture will cause the refrigeration system to produce ice wall and other consequences. 2. 2, should have larger refrigerant refrigerating capacity refrigeration equipment of the same specification, the unit volume was elected with the refrigerant units volumetric refrigerating capacity is big, can obtain larger refrigerating capacity. Under the same conditions, when the capacity must be unit volume of refrigerant refrigerating capacity is big, can reduce the refrigerant volume of the system, and also can be corresponding to shrink the size of the compressor. 3. Three critical temperature is higher, refrigerant, freezing point lower critical temperature is high, easy to refrigerant said in ambient temperature condensate liquid. Low freezing point, low temperature, can be produced to expand the use of refrigerant temperature range, reduce the throttling loss, improve the refrigeration coefficient. 4. 4, refrigerant, viscosity and density to small viscosity and density is small, can make the system in the refrigerant cycle, small flow resistance, reduce the cycle of energy consumption, appropriate to reduce the pipe size, and allows for a smaller pipe bending radius ( And this is very important to reduce the evaporator pressure loss) , but also can reduce the chiller to the impact of the compressor valve group, prolong the service life of the compressor. 5. 5, refrigerant, coefficient of thermal conductivity and heat release coefficient of thermal conductivity and heat release coefficient is high, can reduce the structure of the heat exchanger in refrigeration system appropriately, and can improve the thermal efficiency of heat exchanger in. 6. 6, other aspects of refrigerant request not burning, not explode, non-toxic, non-corrosive, affordable, easy to buy. 2, the classification of refrigerants, refrigerant according to the size of the condensing pressure under normal temperature and evaporating temperature under atmospheric pressure, can be divided into three broad categories: 2. 1, high temperature low pressure refrigerant evaporation temperature above 0 ℃, condensing pressure lower than that of 29. 41995×104Pa。 2. 2, in the medium voltage temperature refrigerant evaporation temperature - 50 ~ 0 ℃, condensing pressure ( 196. 113-29. 41995). ×104Pa。 2. 3, high pressure refrigerant evaporation temperature below - at low temperature 50 ℃, the condensing pressure is higher than 196. 133×104Pa。

The manufacture marketing game of refrigerant gas is changing with each innovation, and businesses of all products need to be ready to pounce.

To learn more about air conditioner capacitor, give us a call at Hangzhou E cool refrigeration Co.,Ltd or visit us online by going to Arkool Refrigeration.

As the full potential of start capacitor suppliers lies in , the demand for is increasing globally, and is being adopted across the global market.

Although the core manufacturing factor of refrigerant gas is high technology, smart customers know that we need to enhance our material quality and producing standard.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect