The use of refrigerant R410a and R22 refrigerant guide

Compared to at present the most popular refrigerant R22, r410a has many advantages in performance, and good heat transfer. The main performance advantage is embodied in the following aspects: 1, compared with R22, R410a system has a significant advantage: 35% higher heat transfer of evaporator, condenser of heat transfer is 5% higher. 2, work pressure than as its cycle 22 will be 57% higher, the unit volume refrigerating capacity than as 22 about 43% larger than as refrigeration coefficient 22 small about 7. And as 7%, the rest of the parameters Basic close to 22. 3, under the same mass flow rate, pressure drop of R410a is small. 4, match the R410a system than R22 system can be used in a small volume of condenser and evaporator, and up to 30% less filled volume of the refrigerant. 5, compressor compression loss is lower, in the process of evaporator and condenser has better heat transfer, pressure drop across the system smaller, so cold in the same amount, the same condensation temperature of system, R410a system eer ( COP) More than 6% higher than that of R22 system. Second, installation and maintenance matters needing attention: 1 is higher than that of R22, R410a refrigerant pressure about 1. About 6 times, when installing a R410a refrigerant air conditioning, using R410a special tools and materials, pay attention to safety operation. 2, please don't put R410a refrigerant outside air mixed with air conditioning refrigerant circulation line. If mixed with air and gas, will lead to abnormal high pressure refrigerant circulation pipeline, the main cause of the circulation line rupture, crack. 3, if the refrigerant leakage in the interior, once contact with open flame will form of toxic gases. 4, and other cold media use before different, vulnerable to moisture, oxidation layer, grease, etc. The influence of impurity content, therefore, sufficient attention should be paid during operation, use clean pipe, prevent moisture, etc. 5, because the azeotropic mixture refrigerant R410a is a kind of simulation, when add refrigerant, using liquid way add. Said in add refrigerant with a refrigerant container and electronic, according to the weight measurement. 6, use air conditioning, a R410a refrigerant pressure than traditional R - 22 a much bigger air conditioning refrigerant, therefore, in choice of materials, must be compatible with R410a. In the market to buy the wall thickness of 0. 7 mm copper tube, absolutely can't use. 7, R410a pressure is higher, cannot use the before even more inventory. High standard and the low pressure table difference with previous products. When buying pressure gauge can refer to the following parameters. Eight, in R410a refrigerant but with vacuum pump oil ( Mineral oil) , will produce chemical reaction, generate sludge, cause the damage of the air-conditioning unit. 9, R410a refrigerant container, direct use of refrigerant in the name of the annotation, at the same time, also according to the requirements of the United States ARI color annotations ( Pink) 。 R - before 10, cannot use The detection of 22 products. You must use the high sensitivity for HFC refrigerant leak detector.

Hangzhou E cool refrigeration Co.,Ltd is specialized in sourcing start capacitor suppliers refrigerant gas through its unparalleled worldwide network of supply. Go to Arkool Refrigeration, you will surely find your ideal at the most favorable price.

If you have any issues with your air conditioner capacitor, you will have to call the experts at Arkool Refrigeration to assist you. Any of your enquiry is warmly welcomed.

For Hangzhou E cool refrigeration Co.,Ltd as a whole to adopt an attitude of acceptance toward change and technological innovation, we first have to truly embrace it and practice what they preach. Technological development needs to be more than just another investment, but a complete integration.

Hangzhou E cool refrigeration Co.,Ltd, which contributes itself on refrigerant gas for creating more useful application.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect