The use of freon note way and the common problems

use process should pay attention to:

closed operation, the comprehensive ventilation.

operator is necessary through special training, strictly abide by the operation procedures.

operators wear anti-static ChangFu, wear protective gloves, usually When necessary, wearing chemical safety protective glasses; Special cases, wear a self-priming filter type gas mask ( Half mask) 。

away from fire and heat source, no smoking in the workplaces where, prevent high concentrations of inhaled, preventing explosion.

use explosion-proof ventilation system and equipment, to prevent gas leakage in the air of workplaces.

prevent and antioxidant touch.

in the process of transmission, the cylinder and the container is necessary grounding and jumper, static electricity to prevent the attack. Transfer put good cylinder helmet and shockproof rubber band, to prevent the cylinder knock against, damage.

equipped with corresponding variety and quantity of fire equipment and leakage emergency handling equipment.

in frozen equipment, water vapor from the side into the equipment of water at low temperature condition, it is compressed into the condenser, with freon steam condense into liquid water, water to droplets mix in freon liquid, in the expansion valve because of the low temperature freeze into ice, block valves, refrigeration equipment to normal operation. Moisture can also make the hydrolysis of freon seizures acid, make the refrigeration system attacks 'copper' appearance.

small freon for water solubility, refrigeration equipment in the acid will attack after entering the water, and easy to cause low temperature system of the 'ice block', blocking the throttle valve or piping.

other prevent freon with natural rubber, the equipment should be chosen nitrile rubber gaskets or seals.

leakage treatment: rapid evacuation leakage pollution area personnel to advantage, and cut off, the strict limits on balance of payments. Block the fire. Advocate the emergency response personnel wear self positive pressure respirator, wear antistatic ChangFu. Block the leakage source as much as possible. Reasonable ventilation, speeds up the dispersion. If there is no danger, in situ burning, spray water cooling around together, in case of other fuel burning. Or use the line guide to furnace burning, concave. Flat container to properly handle, reoccupy after repairing, inspection.

this release of the refrigerant, freon manufacturers, for details, please click on the query.

looking for the best deal while getting a quality is usually the number-one objective for most start capacitor suppliers manufacturer.

See reviews of the latest trend in refrigerant gas industry at Arkool Refrigeration, and see the best that work in just minutes! Visit us right away!

Data has always been important in business, of course. But with the arrival of digital data—its volume, depth, and accessibility—it has become clear it is key to helping Hangzhou E cool refrigeration Co.,Ltd develop sustainable competitive advantage.

An easy and inexpensive air conditioner capacitor solution can be easily obtained now through purchasing a refrigerant gas start capacitor suppliers online. Find your solution at Arkool Refrigeration, your demand will be satified.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  CHEMLONG CO.,LIMITED / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect