loading

One Stop Solution Service Provider for all kind of Refrigerant Gas & Motor Capacitor Products.

The use of film capacitor we should pay attention to what problem

The use of film capacitor note

1. Working voltage, high voltage film capacitor to choose depends on, and by applying the voltage waveform, current waveform, frequency, environment temperature, Capacitor surface temperature) And the influence of the factor such as the capacitance. Before use, please check at the ends of the capacitor voltage waveform, current waveform and frequency ( In high frequency, allowing with different types of capacitor voltage change, details please refer to the manual) Whether in the rating

2. Pulse electric current through the capacitor (work Or communication) Current is equal to the capacitance C and the product of the voltage rising rate, namely I = C× dV/dt 。 Because the capacitor loss, under the condition of high frequency or high pulse when used by pulse capacitor ( Or communication) Current can make the condenser heat and temperature rise, there will be thermal breakdown ( Smoke and fire) The danger. Therefore, the capacitor safety conditions of use not only by the rated voltage ( Or category voltage) Restrictions, and restricted by the rated current. Rated current is considered to be determined by the breakdown model of pulse electric current ( Peak current, that is limited by the index of dV/dt) And continuous current ( Expressed in fengfeng values or RMS) Composition, when using, must make sure both current within the scope of the permit. Under the condition of high frequency or high pulse capacitor used, we recommend polypropylene film capacitor or CL23B fold chip capacitor. CBB81 are, CBB81B, CBB81A polypropylene film series high voltage capacitor is given duty ratio ( 责任) Was 15% of the rated current fengfeng values. CBB21, CBB21B, CBB21A series S correction capacitor rated fengfeng value current is given. Under no circumstances do not allow more than the rated value of fengfeng current use. When actual working current waveform and the waveform is not at the same time, given the polyester film capacitor in their temperature is 10 ℃ or less use, under the condition of polypropylene film on its temperature rise is 5 ℃ or less use, under the condition of the condenser surface temperature no more than rated maximum temperature

5, inhibiting power electromagnetic interference with capacitor

5. 1 when used in power possible cross line circuit capacitor to eliminate noise, not only the normal voltage, there will be abnormal pulse voltage ( Like lightning) Smoke or fire happens, this may lead to capacitor. Line across the capacitor, therefore, its safety standards in different countries have strict rules. Please use after X2 - safety certification MKP X2 - MKT CBB6 type capacitor. Capacitor are not allowed to be used as a capacitor across the line.

5。 2 X2 class power electromagnetic interference suppression with capacitor is suitable for the capacitor fails will not lead to dangerous situations, such as power across the line connection, affordable 2. 5 kv pulse.

5。 3 Y2 class power electromagnetic interference suppression with capacitor is suitable for the capacitor failure will lead to dangerous situations, such as power across the line connection, can withstand 5 kv pulse.

At a time when technology is essential for refrigerant gas, ensuring that it works in a symbiotic way with your human employees is key.

Hangzhou E cool refrigeration Co.,Ltd will make a healthy profit for its owners and provide a rewarding work environment for its employees.

We should take a step back to review how Arkool approach tracking, implementing, and communicating compliance-related changes and attempt to identify areas of improvement in their processes.

Hangzhou E cool refrigeration Co.,Ltd has extented its range of manufacturing scale, which satisfys customers' needs.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect