loading

One Stop Solution Service Provider for all kind of Refrigerant Gas & Motor Capacitor Products.

The use of everything

In the use of refrigerant should pay attention to the following: 1, the instruments used for everything, equipment and measuring tool cannot and swap with R12, as if everything in mixed with R12 can make the compression surface damage, and may also use the instrument and the equipment damage. 2, everything, and the refrigeration oil can't mix of refrigerant R12, because everything is not compatible with R12 refrigeration system of refrigerant oil. R12 refrigeration system using home-made 18, 25 frozen oil or Japanese SUNISO gs, SUNISO 3 4 gs, 5 gs SUNISO refrigeration oil, but everything system generally USES the synthesis of poly (alkyl deg. 3, maintenance refrigeration system a good safety protective glasses and gloves should be worn when, avoid by all means let the liquid refrigerant in contact with the skin, particularly in the hands and eyes, in order to prevent frostbite. 4, the same as PAG oil with everything in high temperature and low temperature area produces two layers of separation ( Both the separation) Phenomena ( FIG. 1) , therefore, need to put it on when charging the main heating of the hot water container, but not more than 40 ℃ temperature is absolutely forbidden to use heating burner type of heating equipment, to prevent two layers of separation phenomenon as far as possible, lest bring compressor exhaust pressure and cooling effects. 5, everything must use special sealing and gasket, the use of cooling oil can make the R12 system using the blister sealing ring and gasket failure, resulting in refrigerant leakage. 6, when charging everything, should keep everything in the containers in the upright position, make sure that everything in gaseous way to enter the system, otherwise, everything may be to a liquid into the compression surface, make the compressor damage, in addition, filling operations should be carried out in the place where the air circulation, in case the operator has choked on the cylinder oxygen. Dryer (7 and reservoir Or gas-liquid separator) Must be sealed, the installation must quickly; Otherwise, dryer air into the reservoir ( Or gas-liquid separator) After make desiccant temperature absorption ability is abate, even failure. Southern refrigeration remind you, although everything refrigerant is internationally recognized one of the main refrigerating substitute R12, can also be used to configure other mixed refrigerants, but cannot be used with mixed refrigerant R12, this will cause damage to the equipment.

However, with the increased prevalence of refrigerant gas, it has become far more affordable.

Hangzhou E cool refrigeration Co.,Ltd is one of China's biggest providers in the following categories of products: air conditioner capacitor, start capacitor suppliers, start capacitor suppliers,etc. We also welcome ODM and OEM orders, and offer the highest standards of service, the cheapest deals, and the best buying experience. Get to know us at Arkool Refrigeration.

Hangzhou E cool refrigeration Co.,Ltd might focus its marketing efforts by highlighting its end product—improved technology and increased profits—not its producing methods.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect