loading

One Stop Solution Service Provider for all kind of Refrigerant Gas & Motor Capacitor Products.

The use of everything and maintenance matters needing attention

no matter what product, we all have their own some matters needing attention, R134a has a refrigerant is not exceptional also, so you know how everything refrigerants use and maintenance of the matters needing attention of? Don't know it doesn't matter, to introduce below small make up for you. And see it together.

1, the instruments used for everything, equipment and measuring tool cannot and swap with R12, as if everything in mixed with R12 can make the compression surface damage, and may also use the instrument and the equipment damage.

2, everything, and the refrigeration oil can't mix of refrigerant R12, because everything is incompatible with R12 refrigeration system of refrigerant oil. R12 refrigeration system using home-made 18, 25 frozen oil or Japanese SUNISO3GS, SUNISO4GS, SUNISO5GS frozen oil, and everything system generally USES the synthesis of poly (alkyl glycol, namely PAG ( Polyalokylene乙二醇) Oil or polyester ( 聚酯) Oil.

3, maintenance good protective glasses and gloves should be worn when refrigeration system, avoid by all means let the liquid refrigerant in contact with the skin, particularly in the hands and eyes, in order to prevent frostbite.

4, the same as PAG oil with everything in high temperature and low temperature area produces two layers of separation ( Both the separation) Phenomenon, therefore, need to put it in when filling R 134 containers of water are heated, but not more than 40 ℃ temperature banned heating burner type of heating equipment, to prevent two layers of separation phenomenon as far as possible, lest bring compressor exhaust pressure and cooling effects

5, R134a has a system to use special sealing and gasket, use of cooling oil can make the R12 system using the blister sealing ring and gasket failure, resulting in refrigerant leakage.

6, when charging everything, should keep containers of everything in the upright position, make sure that everything in gaseous way to enter the system, otherwise, everything may be to a liquid into the compression surface, make the compressor damage, in addition, filling homework to where the air circulation, in case the operator has choked on the cylinder oxygen.

dryer (7 and reservoir Or gas-liquid separator) To be kept sealed its installation quickly; Otherwise, dryer air into the reservoir ( Or gas-liquid separator) After make desiccant temperature absorption ability is abate, even failure.

more about everything refrigerants used and maintenance related introduction over here, hope to be able to bring you some help, if you have demand to everything refrigerants, welcome consulting money with us, we wholeheartedly at your service.

air conditioner capacitor start capacitor suppliers, as the name suggests, find extensive use in start capacitor suppliers institutions. Since start capacitor suppliers has become much dependent on technology in today's world, there is wide use of such refrigerant gas.

Hangzhou E cool refrigeration Co.,Ltd is an expert manufacturer that offers top-notch start capacitor suppliers air conditioner capacitor products in start capacitor suppliers. The company has a a lot of experience to offer quality ensured that cater to various customer demands. Simply visit Hangzhou E cool refrigeration Co.,Ltd website to learn more.

Hangzhou E cool refrigeration Co.,Ltd have significantly changed the way customers approach manufacturing. refrigerant gas can still compete if we are willing to change the ways in producing.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect