air conditioning: what's the use of the technical characteristics of refrigerant r410a this believe that many people have this problem, small make up today for everyone to do a detailed introduction about this issue, let's get together and see it.

refrigerant R - HFC - 410 - a is a hybrid 32 and HFC - 125 ( Mass ratio of 50% / 50%) 。 It is instead R - 22 refrigerant fixed air conditioning system, but is cannot be applied on the original R22 equipment. It is not a substitute for R22. R - 410 a has proved can effect comparing increased 5 ~ 6%, compared to R - 22. It also has a R - 22 a higher capacity and release the pressure, make the design of the air conditioning device is smaller and compact. R - 410 a pressure than R22 larger nearly 60%, but the discharge pressure and the suction pressure and R22 have the same compression ratio.

it is HFC - 32 and HFC - 125 almost azeotropic binary mixture, its floating temperature below zero. 2℃。 It is very similar to the properties of azeotrope, can see it as a single refrigerant. This means that they won't destroy the combination of the system and its proportion, also won't change when leakage. Cylinder diameter cannot too big, the compressor discharge capacity is not more than 32 cm3, so the piston machine can separate combination and the compression force is in danger. Steaming compression cannot exceed a certain space, danger! It is very important, so to add fluoride must be done in the liquid.

R410A its excellent thermodynamic properties can be used more compact compressor, smaller the diameter of the tube, because it has lower energy loss. R - 410 a is compatible with mineral oil or oil alkyl benzene, because R410A won't mix with them. For R - Is 410 a specified oil polyols ( POE) Oil. The oil should not be exposed in the open air, and can only be opened before use.

tools and parts for refrigerant R - certainly 410A。 Do not use the conventional instrument filling refrigerant, measuring pressure and watching them ( Tube, extraordinary) In case of one thousand.

the above introduction about the R410A refrigerant to the over here, hope to be able to bring you some help, if there is demand for R410A, welcome consultation discussion with us.

This is an internationally recognized standard which acts as a form of guarantee that everything Hangzhou E cool refrigeration Co.,Ltd does is managed to the highest quality standards.

To reduce your production costs, get your and start capacitor suppliers from Hangzhou E cool refrigeration Co.,Ltd,you will get high quality warranty at favorable price in return. Visit Arkool Refrigeration.

Hangzhou E cool refrigeration Co.,Ltd's core technology of refrigerant gas enables us to understand and utilize in a right way.

Hangzhou E cool refrigeration Co.,Ltd will do this by managing our business with integrity and the highest ethical standards, while acting in a socially responsible manner with particular emphasis on the well-being of our teammates and the communities we serve.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect