The role of refrigerant in air-cooled chillers

  【】The refrigerant itself circulates continuously in the refrigeration system, and then realizes refrigeration through its own state changes. The refrigerant absorbs the heat of the cooled medium in the evaporator and vaporizes, and transfers the heat to the surrounding air or water in the condenser to condense. When the air-cooled chiller refrigeration cycle system is running, the refrigerant is also inseparable. The refrigerant flows continuously in the air-cooled chiller circulation system, and its state is constantly changing. Therefore, the state of the refrigerant in each position of the air-cooled chiller refrigeration cycle system is different. . So, what role does refrigerant play in air-cooled chillers?

  1. The change of refrigerant in the air-cooled chiller refrigeration compressor

   The refrigerant enters the suction port of the compressor from the end of the air-cooled chiller evaporator , And complete the process of compressing refrigerant vapor into superheated vapor in the refrigeration compressor, and the pressure is also increased from the evaporating pressure to the condensing pressure. Since the compression process of the compressor is completed instantaneously, the refrigerant vapor at this time will not exchange heat with the outside world, which is called the adiabatic compression process.

  2. The change of refrigerant in the condenser of the air-cooled chiller

   After the superheated steam enters the condenser of the air-cooled chiller, the pressure condition does not change, so It will first emit a part of the heat, so that the superheated vapor of the refrigerant is cooled into saturated vapor. Because it is still under isothermal conditions at this time, the saturated vapor will continue to emit heat and condense and continuously produce saturated liquid. The longer the condensation time, the more saturated liquid will be, and the saturated vapor will decrease. The end result of z* is: all refrigerant vapor is condensed into saturated liquid.

  3. The change of refrigerant in the throttle element of the air-cooled chiller

   Since all the refrigerants have become saturated liquid, when the saturated liquid refrigerant flows through the air-cooled When the throttling element of the chiller, the condensation pressure drops to the evaporation pressure, and the temperature drops from the condensation temperature to the evaporation temperature. The refrigerant flowing out from the outlet of the throttle element becomes a two-phase mixed state with about 80% of liquid and about 20% of gas. A small amount of vapor is generated due to the flash gas that appears due to the expansion of the liquid due to the pressure drop.

  4. The change of refrigerant in the evaporator of the air-cooled chiller

   When the refrigerant enters the evaporator of the air-cooled chiller, it is absorbed by the cooling medium. With heat and constant evaporation, the refrigerant is constantly vaporized under constant temperature conditions, so that there is less and less liquid, but more and more vapor. When the refrigerant liquid is completely vaporized and becomes saturated vapor, it will return to the compressor suction port of the air-cooled chiller to recirculate the above changes.

For business owners unsure of how to effectively incorporate new technology into our refrigerant gas, life may have just become a little easier.

Do you want start capacitor suppliers air conditioner capacitor? We also have start capacitor suppliers. visit Arkool Refrigeration to know more.

Hangzhou E cool refrigeration Co.,Ltd expects to reach the desired profits in the first year and does not anticipate serious cash flow problems.

Through our distribution and marketing competencies, Hangzhou E cool refrigeration Co.,Ltd provides creative, customized, solutions for our customers. As a result, we achieve superior profit growth as the refrigerant gas company of choice.

There have been conclusive evidence on 's role in start capacitor suppliers and start capacitor suppliers.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect