The relationship between refrigerant and water in explosion-proof chemical air-conditioning

  【】Compared with ordinary air conditioners, explosion-proof chemical air conditioners have good explosion-proof performance as an important factor for companies to choose. There is no difference in appearance and use, but in terms of production technology, both have The difference is that the explosion-proof principle of the explosion-proof air conditioner is to move all the circuit board chips inside the air conditioner into the explosion-proof control box, and the explosion-proof control box controls the operating state of the air conditioner. Secondly, the explosion-proof air conditioner uses explosion-proof treatment on the motor of the air conditioner, and the motor is sealed with glue, so that the coil in the motor is completely separated from the external environment. To put it simply, explosion-proof air conditioner means that both the indoor unit and the outdoor unit are subjected to explosion-proof treatment. Only in this way can the explosion-proof requirements be fully met.

The refrigeration system of    explosion-proof chemical air conditioner is divided into two categories: direct cooling and indirect cooling system. Refrigeration cycle cooling system, indirect cooling system, including two kinds of refrigerants and refrigerant cycles.

When the refrigerant in the    explosion-proof chemical air conditioner contains moisture, an ice jam will occur, which can easily block the regulating valve or the road. When it is light, it affects the refrigeration effect, and when it is severe, it makes the whole system unable to run.

   In addition, moisture will combine with the refrigerant to decompose, forming a precipitate. The sediment will cause the deterioration of the lubricating oil and affect the lubrication of the compressor. Some refrigerants also corrode metals when mixed with water. Damage the motor winding insulation.

   In short, moisture in the refrigeration system is harmful to no benefit, so we must pay close attention to it. There are three sources of moisture:

  The refrigerant itself contains moisture, the lubricating oil contains moisture, and the air entering the system during assembly and repair also contains moisture.

   Therefore, in addition to paying attention to the moisture in the refrigeration oil and lubricating oil, the vacuuming work of the refrigeration system must be thorough to prevent moisture in the air from remaining in the system to avoid ice plug failure.

The refrigerant gas approach to start capacitor suppliers is becoming increasingly popular; consequently, there is a surge in the demand for .

Hangzhou E cool refrigeration Co.,Ltd is a professional manufacturer of offering some of the best in class air conditioner capacitor solutions to global market. Click Arkool Refrigeration to learn more.

With the help of a start capacitor suppliers refrigerant gas, start capacitor suppliers becomes a reasonably easy job that you can take care of simply and swiftly.

Our company is professional in manufacturing air conditioner capacitor especially start capacitor suppliers.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect