The reason why the air conditioner only blows but not cools

In the hot summer, the air conditioner is a very good heat escape device, especially in the south. If there is no air conditioner, there is no way to work, study and live. Because the summer in the south is very hot, as long as you move, you will really sweat, so The whole summer is basically spent in an air-conditioned room. The reason why the air conditioner only blows but not cools? This requires professional analysis, otherwise unprofessional people will not be able to find the reason. Let's take a look at how often the air conditioner refrigerant is added and how much it costs to add freon to the air conditioner.

1. The reason why the air conditioner only blows and does not cool

In the hot summer, the air conditioner is a very good summer heat device, which will not make you feel how hot the summer is, but the air conditioner use time After a long time, the reason why the air conditioner only blows but does not cool is that the room feels very stuffy and hot. Let's take a look at how the air conditioner only blows but not cools.

1. There is a problem with the remote control

Solution: Is the remote control okay? If there is no problem, turn on the power of the air conditioner and use the remote control to see if it can be turned on. If it can't be turned on, check whether your power supply is normal. If it is normal, then judge that there is a problem with your circuit board.

2. Mode error Solution: If your fan is activated and the host is activated, see if your remote control is adjusted to the refrigeration area, you can just adjust it to the refrigeration area.

3. Insufficient refrigerant

Solution: If your wind machine is activated and the host is also activated, you should check if there is a refrigerant? If not, add refrigerant, but before adding refrigerant, check if there is any leakage, and if there is any leakage, just fix it. 4. The compressor is malfunctioning. Solution: Check whether your compressor is started, if not, please ask professionals to help solve it. 5. The indoor and outdoor temperature is too high. The external environment is high and there are many people in the room. The air conditioner has a heavy workload at full load. The air blown out of the outlet is cold, but the room temperature cannot drop. This is not a malfunction. When the ambient temperature is higher than 33℃, the external heat infiltration increases, which increases the cooling load of the air conditioner; if there are a large number of people in the room, such as a 20 square meter room with a cooling capacity of 2500W, if there are 10 people sitting still in the room . 6. Poor installation location of the outdoor unit. Solution: Poor installation location will also cause uneven indoor temperature or poor cooling effect. This requires readjusting the installation location of the air conditioner. 7. The condenser is dirty and blocked. Solution: Clean the condenser and evaporator coils of the air conditioner regularly. Brushes and vacuum cleaners can be used to clean the dust on the coil. Note that when cleaning, the brush and vacuum cleaner should be cleaned in the vertical direction of the coil, and do not clean in the horizontal direction, so as not to damage the fins of the coil.

Clouds of start capacitor suppliers failures surround the world of start capacitor suppliers in particular, simply because people don’t pay as much attention to the air conditioner capacitor as they should do.

Visit Hangzhou E cool refrigeration Co.,Ltd for the best in supplies: Arkool Refrigeration.

Although there are various available in the market (such as start capacitor suppliers, start capacitor suppliers, and start capacitor suppliers), recent study results have made this start capacitor suppliers refrigerant gas a preferred air conditioner capacitor choice of the people.

Hangzhou E cool refrigeration Co.,Ltd are used to coming up with solutions while think about problems, also expressing the whole idea individually.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect