The matters needing attention of refrigerant R290 operation

R290( Propane) Also called cold coal, is a new kind of environmental protection refrigerants, mainly used in air conditioning, heat pump air conditioner, air conditioning and other small household refrigeration equipment. R290 as a kind of hydrocarbon refrigerants, ODP value is 0, GWP value is less than 20, and compared with R600a, everything, r404a, has a prominent advantage on cooling performance. Because of its features, flammable and explosive perfusion has been curbed, security level for A3.

R290 refrigerant application note

1, the product USES the R290 refrigerants, use and maintenance of room area should be greater than 15 square.

2 use area to avoid a fire within 2 meters, air conditioning, indoor parts installation height shall not be less than 2. 2m。

3, just below the house is not allowed to have socket etc may produce a spark of power and heat source.

4, do not allow the extension tube, are not allowed to add refrigerant.

5, vacuum to ensure more than 15 minutes, pressure for 5 minutes. Make sure the system vacuum degree meet the requirements. Avoid operating in leaked refrigerant into the air.

6, strictly prohibits smoking in air conditioning within the scope of 2 meters. Found anomalies ( Such as the burning smell, etc. ) , please immediately cut off the power and contact the maintenance process. Prohibited by the teardown and industry service.

7, in any case 掋 system refrigerant, must 掋 in the open position, outdoor recommended 掋 feed clamp 掋, avoid 掋 put traffic greatly generate static electricity.

8, the bottle should be let in ventilated place, storage temperature should not exceed 50 ℃, it is forbidden to place around flammable, refrigerant can prohibit repeatedly filling used.

9 before the installation, maintenance, need to carry flammable gas palm sensors confirm that the user home R290 didn't reach alarm concentration, within the scope of safety operation.

10, repair electrical parts, the need to power off before maintenance. As to the power supply in the process of maintenance, dangerous location should be stopped 丌 leak detection to prevent potential dangers. Replace metal collision should avoid happen in all the improper operation may produce a spark.

more attention on the operation of refrigerant R290 over here, hope to be able to bring you some help, if you have a demand on refrigerant, welcome consultation discussion with us, we wholeheartedly at your service.

Arkool allocates customer service resources to the platform where their customers are most vocal.

What are you waiting for? Get out there and buy some of the most effective at Arkool Refrigeration.

For more refrigerant gas start capacitor suppliers reviews, tips and advice on choosing a washer and dryer for you and your family, please visit Arkool Refrigeration,where you can also choose the you are looking for.

The first machine to produce start capacitor suppliers, the start capacitor suppliers air conditioner capacitor was invented in start capacitor suppliers in start capacitor suppliers by start capacitor suppliers and was subsequently improved.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect