loading

One Stop Solution Service Provider for all kind of Refrigerant Gas & Motor Capacitor Products.

The matters needing attention of refrigerant charging _

At present some of the air conditioner using r404a, R407c, r410a brew non azeotropic refrigerants, such as cold agent for such system must use liquid filling. Because of non azeotropic mixed refrigerant nature of each component, the boiling point is different, so the non azeotropic mixed refrigerant gas and liquid composition is different, with gas filling local CPA filling the refrigerant composition deviation. Of course, if a can of refrigerant charge completely into a machine is not the problem. 1, non azeotropic mixed refrigerant must use liquid filling if the refrigerant R22 such as single or R507 azeotropic mixture refrigerants, either with gas filling, and can use the liquid filling. 2. To prevent liquid impact the so-called 'liquid impact' refers to the liquid refrigerant in the compressor, compressor of abnormal impact accidents. Say simply is that gas is compressible, and the liquid is incompressible. When the refrigeration system with liquid refrigerant entering the compressor cylinder, will impact the compressor valve plates, causes the damage of valve and other parts, is the most serious consequences may cause permanent damage to the compressor. Liquid impact mainly appeared in the piston compressor. System refrigerant or lubricating oil is overmuch, expansion valve, Or the regulator) The regulation of degree ( Opening) Too big, the heat load of evaporator ( Heat transfer) Is not stable, may cause fluid. Add liquid too fast in the filling process of refrigerant is one of the important cause of liquid impact. The abnormal impact (if the filling of the compressor Tap or hit) Sound, or accompanied by strong swing vibration phenomenon, liquid strike has already occurred. Slightly short of abnormal shocks can issue is not big, but often, long and heavy liquid, can make the compressor even broken, deformation, valve plates rupture and direct damage to the compressor.

Maintaining start capacitor suppliers is not as easy as it may seem. You have to do plenty of important tasks. So cruel is the truth unless you've got a to help you.

Our vision is to realize the tremendous potential of refrigerant gas by providing start capacitor suppliers services that consistently meet our customers’ expectations.

Overall, air conditioner capacitor may be a great way for manufacturers to expand their use of technology, but the price could present a significant hurdle for some businesses.

For optimal start capacitor suppliers, choose a high-quality refrigerant gas system and make sure a certified installer sets it up.

These start capacitor suppliers air conditioner capacitor are not only useful but also more cost effective than those traditional ones.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect