The fridge add R600a steps and methods of the refrigerant

R600A refrigerant system not refrigeration freezer, want to find someone to repair, curious to ask the maintenance man, later will add the methods and steps of refrigerant R600A compiled, there are so many steps in detail:

1. Separated by piping, fitting of copper pipe, general compressor around low pressure pipe and copper pipe connection, then copper pipe welding, good at the outlet set of copper after the child. Again good bell mouth. 。

2, good connection line and the vacuum pump, check and no leakage in the pipeline, vacuum first, then into 2 mpa nitrogen pressure 2 - For three days. Leak detection, if three days later, the pressure did not change, you can add r600a. Refrigerants. ( Teacher told me that he is commonly used ek sheng R600a freon)

3。 Open the valve, put off the nitrogen, when the pressure of 0, start the vacuum pump, vacuum to - 0. 1 mpa, then switch off the vacuum pump. Put a bottle opener on the bottle of refrigerant r600a, good connection with fluid tube and pressure gauge,

4. The freon r600a prick with a bottle opener, letting off a little r600a refrigerants, to rinse the inside of the line a little air, remaining open

electronic scale, put refrigerant r600a on electronic scale, weight, and write it down, keep in mind that this position at this time, don't move, start the fridge, began to add fluoride, general refrigerator r600a refrigerant filling quantity at about 50 grams, started using liquid filling, can put the freon r600a bottle upside down, to more than 30 grams, after return to tag, slowly with gas filling, aware of electronic scale, according to the explanatory notes to the 3 - more than nominal value 5 g can stop, turn off the valve, sealing pliers, 5 - from the low pressure pipe 10 cm of the copper pipe wrench flat, then use the pipe cutter cut out. Can put the refrigerator power at this moment, stop running.

Hangzhou E cool refrigeration Co.,Ltd will continue to build a corporate culture that respects and values the unique strengths and cultural differences of our associates, customers and community.

Always do our research, follow the rules and plans ahead for additional expenses. Expanding is the goal of Hangzhou E cool refrigeration Co.,Ltd; expanding properly is the goal of the wise business.

Getting air conditioner capacitor from an idea to production is a complex process. It involves significant research, time, planning and patience. But with the right information, the right resources and the right product, it's possible.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect