The effect of [air conditioning heating] is not good in winter, what is going on?

What are the reasons why the air conditioner does not heat up in winter?

Reason 1: The outdoor temperature is too low. When the outdoor temperature is too low, the outdoor unit of the air conditioner cannot perform defrosting normally, and the heating effect of the air conditioner will also be affected. Solution: If the heating effect of the air conditioner is not good due to natural reasons, defrost the outdoor unit of the air conditioner, restore the defrosting effect of the outdoor unit of the air conditioner, and enhance the thermal efficiency of the indoor mechanism.

Reason 2: The power supply voltage is too low. Air conditioners have certain requirements on the power supply voltage. When the voltage cannot meet the heating power of the air conditioner, the cooling and heating of the air conditioner will be affected. Solution: When the indoor power supply voltage is unstable, you can buy a voltage stabilizer, which can effectively maintain the stability of the electrical voltage. At the same time, it can avoid the peak electricity consumption period, which can greatly reduce the impact.

Reason three: The interior of the room is not tightly closed, which will also affect the heating efficiency of the air conditioner. Solution: In the process of using the air conditioner, the room must be kept closed, so as to better ensure the heating and cooling efficiency of the air conditioner.

Reason 4: Dust blocks the air conditioner filter. The air conditioner needs to be cleaned regularly after being used for a period of time, which can prevent dust from clogging the air conditioner filter, thereby affecting the heating effect of the air conditioner. Solution: The heating effect of the air conditioner is not good due to the failure to clean in time. The filter of the air conditioner needs to be taken out for cleaning to keep the inside of the air conditioner indoor unit clean and tidy, and it can effectively extend the service life of the air conditioner.

Reason 5: The air conditioner freon is leaking or insufficient. The air conditioner needs to use Freon, which is a refrigerant, whether it is cooling or heating during operation. Solution: Re-add freon to the air conditioner, and at the same time repair the leak of freon to prevent freon from leaking again and ensure the normal operation of the air-conditioning refrigeration cycle.

In addition to the above reasons, what other reasons exist?

1. The condensing heat exchanger of the outdoor unit is too dirty, and the outdoor cold and heat exchange is not smooth, which affects the heating effect.

2. The electronic four-way valve is damaged because the air flow in the four-way valve or the opening of the four-way valve is blocked, which affects the switching path of the pipeline refrigerant and affects the effect.

3. During use, the temperature setting is inappropriate, so that the central air conditioner does not reach the normal operating mode.

4. The indoor unit filter is dirty and blocked, which hinders the indoor air supply and affects the effect.

5. The temperature probe inside the unit is damaged, and the normal indoor and outdoor temperature cannot be sensed normally, which affects the normal operation of the unit.

6. There is a strong heat and cold exchange between indoors and outdoors, such as wide open doors and windows, which causes excessive heat flow in the room.

7. The refrigerant pipeline of the indoor unit is blocked, resulting in poor refrigerant circulation. (Of course, this problem does not often occur in household fluorine systems, and it is common in water systems)

Analysis of common failures of air conditioners

1. Air conditioners are turned on and run, sometimes indoors Fuzzy or black screen appears on the display of the machine?

This is because when the air conditioner is cooling in summer, the air humidity is high, and the air outlet of the indoor unit sometimes blows out mist. When the healthy negative ions are turned on at this time, the high DC voltage (small current) released by the healthy negative ions If the air conditioner power supply is not protected by the ground wire, the computer board or the display screen will produce blurring, black screen or crash. Solution: As long as the room air humidity is high, it is recommended not to turn on healthy negative ions. ; The ground wire of the power line is connected firmly; after the air conditioner is powered off again, power on and test the machine again.

2. Why is there a sound of 'water flow' when the air conditioner is turned on?

Because the refrigerant suddenly changed from a static state to a flowing state when it was just turned on, at this time, due to the 'collision' between the refrigerant and the pipeline when the refrigerant is flowing, you will hear 'water flow' in the internal machine. Sound, but when the refrigerant flow is stable, the sound will disappear.

3. Why does the inverter air conditioner have the feeling of leakage of electricity?

Because ordinary air conditioners and inverter air conditioners are classified as household appliances, when the inverter air conditioner shell is not connected to the ground wire, induction electricity will be generated, and there will be a feeling of leakage. Therefore, when the air conditioner must connect the power supply socket or switch to the air conditioner, ensure that the air conditioner's shell is well grounded to eliminate the induced electricity.

4. Why is the electric meter still running after the air conditioner is shut down?

This is because the power plug of the air conditioner is not unplugged, and the heating belt and transformer of the press are still working. However, the power of the heating belt is generally 27-33W, and the power of the transformer is only 3-7W, so the power consumption is very small. However, if the machine is not used for a long time, it is recommended to unplug the power plug, which not only saves electricity, but is also safer.

refrigerant gas has become a crucial product for marketers, especially when it comes to brand building and engaging potential customers.

We are a provider of a various number of services that include . Search our website by air conditioner capacitor start capacitor suppliers product line or category to find what you are looking for.

But we do think that reckoning with supply chains of refrigerant gas is a really important step. Even super simple switches in material, or sourcing, or shipping, or worker benefits seems like good place to start.

As a top provider of products, Hangzhou E cool refrigeration Co.,Ltd will surely meet your urgent need for air conditioner capacitor solutions. Go to Arkool Refrigeration.

An interesting website that contains directions (and recommends items) for refrigerant gas start capacitor suppliers is Arkool Refrigeration. Find us on Arkool Refrigeration, your problem will be fixed.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect