loading

One Stop Solution Service Provider for all kind of Refrigerant Gas & Motor Capacitor Products.

The difference in the refrigeration system of refrigerant R22 and R410A

we all know that a lot of models and refrigerant, there are difference between different models, small make up today is mainly to introduce the difference in the refrigeration system of refrigerant R22 and r410a, want to know friends following the introduction of small make up have a look at the following article.

( 1) High pressure of R410a refrigeration system are as follows: 3. 0 mp, low pressure as follows: 1. 2MP。 ( In the same situation for R22 1. 5 times)

( 2) When new refrigerant R410A fission installation, if the connecting pipe used special tube R410A, emptying, with R410A refrigerant emptying, shall not be used and R22 air conditioning connecting pipe and confused refrigerants, otherwise will affect the use of air conditioning stability.

( 3) Because of R410A refrigerant compressor used in the fission machine with POE oil lubrication, POE oil and water, formation water and acid, and the generated water can cause POE oil reaction further, if the chain reaction down for a long time, the moisture inside the system will be more and more, could make the ice blocking occur capillary; At the same time system circulation within the working medium acid will be more and more high, PH lower) , could lead to corrosion in the system components, and produced copper plating. Therefore, when installed, the movement wants quickly, after open the connection pipe plug, must within five minutes to tighten the nut, emptying time. When installed, it is forbidden to sweat drip into the connecting tube; It is strictly prohibited to other insoluble impurities mixed with the system. And when installing a R410A refrigerant fission machine, on sunny days, rainy days, may be undertaken when humidity is big, also may be undertaken.

( 4) The chloride ion can react and R410A refrigerant and POE oil, acid corrosion parts of cooling system. Therefore, when installation shall not be mixed with chloride within the system. Such as drip into the sweat, and other impurities containing chloride ion.

( 5) During maintenance, as long as it is cut open refrigeration system, for whatever reason, all want to change the filter drier. Cut open after the refrigeration system to encase with something broken open at once, lest the moisture in the air into the system. The time in the refrigeration system is exposed to the air shall not be more than five minutes.

( 6) When change the filter drier, open at both ends of the filter drier after closing plug, to weld in five minutes into the system so as to isolate air as soon as possible, otherwise will affect the performance of the filter drier.

( 7) When maintenance after the completion of vacuum, the vacuum pump shall be used by special vacuum pump, the application of lipid oil, lubricating oil pump and the pump shall not be used to using R22 air conditioner to pumping air into vacuum state, otherwise it will cause mixed refrigerant pollution, which affects the performance of the air conditioning. To ensure that the vacuum time in more than 25 minutes. Otherwise the moisture inside the system would be on the high side, it will affect the use of air conditioning stability.

( 8) In maintenance, if need to replace parts, special parts, to use R410A can not mix and R22, otherwise it will affect the stability of the air conditioning.

( 9) R410A refrigerant should be stored in under 30 ° C environment, if the above 30 ° C, in the environment to environment in under 30 ° C for 24 hours before using, otherwise cold media group branch change, impact on the performance of air conditioning.

more about the difference in the refrigeration system of refrigerant R22 and R410A introduced over here, hope to be able to bring you some help, if you have a demand on refrigerant, welcome consultation discussion with us.

Hangzhou E cool refrigeration Co.,Ltd is a gaint manufacturer of refrigerant gas, which is one of the most outstanding product produced from us.

Now you can enjoy start capacitor suppliers with Hangzhou E cool refrigeration Co.,Ltd's latest collection of start capacitor suppliers air conditioner capacitor products. Do visit now, at Arkool Refrigeration.

refrigerant gas are less complex compared with start capacitor suppliers.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect