loading

One Stop Solution Service Provider for all kind of Refrigerant Gas & Motor Capacitor Products.

The difference between the refrigerant R404A and R507 -

Refrigerant is also called the refrigerating agent, is the lifeblood of the refrigeration system in general, a lot of places called snow, cold media or freon. It is a cycle in the refrigeration system and through its own change of state in order to realize the refrigeration work material. Refrigerant in the evaporator absorbed by the cooling medium ( With air or water, etc. ) Heat and evaporation, in the heart of the condenser heat transfer to the surrounding air or water and condensation. Refrigerant r404a and R507 application in environmental testing equipment: suitable for high and low temperature test chamber, constant temperature and humidity test chamber, such as hot and cold impact test chamber with low temperature refrigeration system equipment. The difference between the refrigerant R404A and R507 1. Refrigerant R404A is by R125 / R143a/everything by 44% / 52% 4% mixed together, R507 consists of R125 / R143a by 50% / 50% mixed together, look from the composition of mixed composition of R404A three ingredients already contains two R507 ingredients. Both kinds of refrigerant ODP is zero, does not damage the ozone layer. 2. R404A and R507 pressure, temperature, pressure on the table data show that the pressure is almost the same between them, the system will not cause any influence, if people usually pay attention to the use of system components, especially the expansion valve on the label that is Shared by R404A and R507. 3. R404A is azeotrope, liquid filling must be used when filling, and R507 is azeotrope. 4. Everything to be increased by mass transfer resistance in R404A reduced the heat transfer coefficient is a message, and the heat transfer coefficient of R507 above R404A. 5. Use the results from the current producers, R507 effect than R404A cooling speed is faster. 6. From the price comparison, R507 is 30 - higher than R404A - - - - - - 40%. 7. R404A and R507A various performance close to, the compressor power consumption is higher than R507A R404A 2. 86%; Low-pressure compressor exhaust temperature is higher than R507A 0. 58%, high pressure compressor exhaust temperature is higher than R507A 2. 65%; The COP is higher than R507A 0. 01; The middle temperature is lower than R507A 6. 14%.

Hangzhou E cool refrigeration Co.,Ltd is different from other companies as we provide timely and unique services to our respected clients.

Hangzhou E cool refrigeration Co.,Ltd is proud to be recognized as some of the most important and influential providers for global customers.Visit us at Arkool Refrigeration.

Did I make the right decision? Am I saving money? Would I do it this way again? Yes, yes and yes if you choose to visit Arkool Refrigeration and make your enquiry.

Hangzhou E cool refrigeration Co.,Ltd can assure you that we never compromise on our quality standards and are one of the best in the market at present.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect