loading

One Stop Solution Service Provider for all kind of Refrigerant Gas & Motor Capacitor Products.

The difference between the refrigerant R22 and everything

select a proper refrigerant substitutes is very difficult, want to consider many factors and evaluation, and should not only conform to the ozone-depleting ozeme depletion potential ( ODP) Ozeme depletion potential and global warming, GWP) Requirements, at the same time should also consider the thermal properties, toxicity, flammability, compatibility, investment and operation cost, etc. The following will be the application of refrigerant R22 and R134a has a characteristic difference analysis is as follows:

1, R134a has a global warming ozeme depletion potential ( GWP) To zero. 25, R22 is 0. 36, both belong to the greenhouse gases.

2, everything of ozone-depleting ozeme depletion potential ( ODP) 0, R22 is 0. 6, this is the reason for everything become environmentally friendly refrigerants.

3, R134a has a specific volume is 1 of R22. 47 times, and the latent heat of evaporation is small, so everything refrigerating capacity of the unit is only 60% of R22 unit. Calculated on unit refrigerating capacity price, the price of R22 unit about everything about 60% of the unit.

4, R134a has a thermal conductivity than R22 fell by 10%, so everything of the unit heat exchanger heat transfer area need to be more big.

5, R134a has a strong water imbibition, 20 times that of R22, so greater demands of the dryer in the unit system, to avoid ice blocking phenomenon.

6, everything is larger than that of R22 in rubber material swelling effect is stronger, in actual operation and mid-cooling medium leakage rate is higher. In addition to copper corrosion resistance is stronger, in use process will happen 'copper plating phenomenon', thus to increase the additives in the system.

7, everything system requires a dedicated compressor and special lipid lubricating oil, lipid lubricating oil with high water absorbability, high foaming ability and high diffusivity, on the stability of the system performance inferior to R22 system used in the mineral oil.

8, everything HFCs refrigerant and its special lipid oil prices are higher than that of R22, the operation of the equipment maintenance cost is higher.

the above about the end of the refrigerant is introduced here, hope to be able to bring you some help, if you have a demand on refrigerant, welcome consultation discussion with us.

Hangzhou E cool refrigeration Co.,Ltd shows how effective market design can encourage participation, reduce gaming, and aggregate information, in order to improve liquidity, efficiency, and equity in markets.

To find an ideal of your need, please visit my site Arkool Refrigeration.

Hangzhou E cool refrigeration Co.,Ltd’s model also predicts (i) a positive effect of management on firm performance; (ii) a positive relationship between product market competition and average management quality (part of which stems from the larger covariance between management with firm size as competition strengthens); and (iii) a rise (fall) in the level (dispersion) of management with firm age.

Getting refrigerant gas from an idea to production is a complex process. It involves significant research, time, planning and patience. But with the right information, the right resources and the right product, it's possible.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect