The difference between the analytic refrigerant R404A and R507

refrigerant r404a and R507 introduction believe everyone through introducing the before to have a certain understanding, below small make up for all of the content is the difference between the refrigerant R404A and R507, want to know friends following the introduction of small make up have a look at the following article. 1, refrigerant R404A is by R125 / R143a/everything by 44% / 52% 4% mixed together, R507 consists of R125 / R143a by 50% / 50% mixed together, look from the composition of mixed composition of R404A three ingredients already contains two R507 ingredients. Both kinds of refrigerant ODP is zero, does not damage the ozone layer. 2, R404A and R507 pressure, temperature, pressure on the table data show that the pressure is almost the same between them, the system will not cause any influence, if you usually pay attention to the use of system components, especially the expansion valve on the label that is Shared by R404A and R507. 3, R404A is azeotrope, filling liquid should be used when filling, and R507 is azeotrope. 4, R404A reduce everything to be increased by mass transfer resistance in the heat transfer coefficient is a message, and the heat transfer coefficient of R507 above R404A. 5, and use the results from the current producers, R507 effect than R404A cooling speed is faster. 6, from the price comparison, R507 is 30 - higher than R404A - 40%. Each performance close to 7, R404A and R507A, R404A compressor power consumption is higher than R507A 2. 86%; Low-pressure compressor exhaust temperature is higher than R507A 0. 58%, high pressure compressor exhaust temperature is higher than R507A 2. 65%; The COP is higher than R507A 0. 01; The middle temperature is lower than R507A 6. 14%. More about the difference between the refrigerant R404A and R507 introduction to this end, liu hopes to bring some help to you, if you have a demand on refrigerant, welcome consultation discussion with us, we wholeheartedly at your service.

This is an global standard which acts as a form of promise that Hangzhou E cool refrigeration Co.,Ltd manufatures according to the finest quality standards.

Hangzhou E cool refrigeration Co.,Ltd assures you that you will be satisfied with its results and humbly request you to try this. We are hoping for a better business deal with you.

By balancing the efficiencies of new technologies with the personal touch of highly trained and motivated professionals, Hangzhou E cool refrigeration Co.,Ltd is able to deliver solutions and services that exceed our customers’ expectations. We thereby earn their loyalty.

Increasing consumer awareness and rising concern about improving start capacitor suppliers are driving the market of products.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect