The difference between air conditioning refrigerant r32 and r410

R32, chemical, called methylene fluoride formula CH2F2. For not explode, non-toxic, combustible, but is still safe refrigerants.

R410 is a new kind of refrigerant, used to replace R22. New refrigerant r410a composed of two kinds of quasi azeotropic mixture, mainly include hydrogen, fluorine and carbon element, has a stable, non-toxic, superior performance, etc. At the same time as a result of not containing chlorine, so will not react with ozone, can neither destroy ozone. In addition, the adoption of new refrigerant air conditioning again in terms of performance will be improved. R410A is now internationally recognized replacement for refrigerant R22 suitable, and in Europe and the United States, Japan and other countries.

the difference between the air conditioning refrigerant R32 and R410A;

1, safety performance difference; R32 belongs to the new development of refrigerants, tasteless non-toxic. Big disadvantage is flammable and explosive, belong to high risk refrigerants, in the process of the installation and maintenance of air conditioning, slightly improper operation, very prone to bums. Just now, which is still not mature new refrigerant. Compared with R410A, security should differ a lot.

2, cycle performance; R32 in filling into the air and moisture, can work normally, energy-saving effect is stronger than R410A. When filling, and R410A system must be in vacuum, can not be mixed with air and moisture, otherwise it will reduce work efficiency greatly.

3, thermodynamic properties difference: R32 filling quantity is less, only for R410A 0. 71 times, working pressure is higher than R410A R32 system, but the big rise but 2. 6%, R410A system pressure requirements and at the same time R32 system exhaust temperature is much higher than R410A, big rise up to 35. 3 ℃, the existing compressor need to be redesigned.

4, environmental protection feature difference: both the ODP values ( Ozone-depleting ozeme depletion potential) Refrigerant GWP value is 0, but R32, Global warming ozeme depletion potential) Moderate, compared with R22 CO2 emission reduction ratio of up to 77. Only 6%, while the R410A to 2. R410A refrigerant is obviously better than the 5%, in terms of CO2 emissions.

Getting doesn't have to be expensive, time-consuming, or difficult. It all comes down to the right method and a start capacitor suppliers refrigerant gas in place.

If you are looking for start capacitor suppliers air conditioner capacitor, we have plenty of them in our store. We have start capacitor suppliers and many others. Visit Arkool Refrigeration to know more.

The global market is estimated to reach a value of almost start capacitor suppliers in the next decade. have a robust position in the start capacitor suppliers market because of its proven high potency in start capacitor suppliers.

We are making refrigerant gas available to you at a very low price.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect