The commonly used several kinds of refrigerants model the difference of the _

At present, the commonly used refrigerants model with r410a, everything, R407C, R22 this several, small make up here under the brief analysis of the differences between them. Everything is a kind of single component refrigerant and the refrigerant R410a and R407C is mixed. Is a mixture of R32 and R125 of R410a and R407C is R32, a mixture of R125 and everything. Mixed refrigerant has the advantage that can be used according to the specific requirements, for all kinds of properties such as flammability, capacity, exhaust gas temperature and efficiency into consideration, tailored to synthesize a kind of refrigerant. Select refrigerants are many factors to consider, because choose any kind of refrigerant will be on the air conditioning system of the overall operation, reliability, cost and market acceptance of a certain impact. To everyone's very interested in, a new refrigerant because of its heat transfer and pressure drop caused by the different transmission performance of refrigerant is different, this will eventually in system design and system have a significant impact on performance. We briefly discuss the several common characteristics on the difference between difference between refrigerants. Everything of small capacity than that of R22, the pressure is lower than R22. Due to these characteristics, the same capacity of everything need to configure a larger displacement air conditioning compressor, evaporator, condenser, and pipeline. Is that, as a result of the final manufacturing and running a and R22 system of cold quantity, same everything system will need higher cost. The volume and pressure of refrigerant R407C and R22 close to. Therefore, as long as the simple adjustment system design can make the original R22 system applies to R407C system. However, the system can effect comparing can reduce about 5% than the original system. This is due to the relative to other refrigerants, R407C can have up to 6 degrees of temperature drift. So R407C system under the same standard when the condenser and evaporator will reduce the heat transfer, affect system can effect comparing. The volume and pressure of refrigerant R410a higher than that of R22, operation pressure is higher than 50% 60%. High pressure and high gas density as a result, not only can use the smaller displacement compressor, also can use the smaller the diameter of the pipe and valve. The use of high pressure exhaust valve to eliminate system condensing pressure brings hidden trouble. Thick compressor housing system has higher operation pressure. Compressor made some heavy has a benefit, namely R410a running noise than significantly lower 2 - R22 compressor 4 db. Compared with R22 system, R410a refrigerant system heat transfer has a significant advantage - 5% higher than 35% higher heat transfer of evaporator, condenser. And everything and R407C system heat transfer coefficient were lower than that of R22. Under the same mass flow rate, the smaller the pressure drop of R410a, make its can use smaller than refrigerant R22 or other piping and valves. For manufacturing R410a system to reduce the material cost are more likely to be more and in the long piping console and more online system have more advantages. Of course, only to design system, can give full play to the heat transfer and pressure drop of R410a the advantage of small - — Can consider to take the following optimization techniques, for example, use the smaller the diameter of the coil, the different fin structure and increase the loop length, reduce the number of the refrigeration circuit. Finally we can see, R410a refrigerant redesigned system, using a smaller volume of evaporator and condenser, cheaper, and up to 30% of the refrigerant filling quantity reduction. Decreases of refrigerant filling in addition to lower costs, also can improve the reliability of the whole system. In the same amount of cold, the same condensation temperature of system, the refrigerant R410a system eer ( COP) Can be better than 6% higher than that of R22. This is due to the loss of the compressor in the compression process is lower and the evaporator and condenser has better heat transfer, pressure drop across the system. Efficient heat transfer and pressure drop of the smaller in the same operation conditions, the condensing temperature is lower and the evaporation temperature is higher, the compressor in less power consumption, higher efficiency than the case, to obtain a better operating range. In addition, for low compression loss characteristics of R410a, small commercial air conditioning system of large compressor gains more than small household air conditioning compressor.

Hangzhou E cool refrigeration Co.,Ltd is specialized in sourcing start capacitor suppliers air conditioner capacitor through its unparalleled worldwide network of supply. Go to Arkool Refrigeration, you will surely find your ideal at the most favorable price.

As manufacturers we are determined to be the very best in refrigerant gas, regardless of the size, pedigree or inclinations of our competitors.

With the market analysts, exports from Hangzhou E cool refrigeration Co.,Ltd facilities in China will surpass the forecast.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect