The air conditioner does not heat, how to add R410A refrigerant?

The cold winter has continued to cool down. Air conditioners have become an indispensable part of homes and offices. However, the heating effect of air conditioners is suddenly not good. How to add refrigerant if there is a lack of refrigerant? Get up and take a look!

The pressure of r410a is about 1.6 times higher than that of R22 refrigerant. Therefore, once the wrong operation occurs during the construction and after-sales service, a major accident may occur . When installing R410A refrigerant air conditioners, use R410A special tools and materials, and pay attention to safe operation.

(1) Before the operation, confirm the name of the air-conditioning refrigerant, and then perform different operations on different refrigerants. In the household air-conditioning using R410A refrigerant, you must not use R410A other than R410A refrigerant must not be used in air conditioners that use R22 refrigerant.

(2) If refrigerant leaks during operation, please ventilate in time.

(3) When installing and moving the air conditioner, please do not mix air other than R410A refrigerant into the air conditioner's refrigerant circulation pipeline. If non-condensable gas such as air is mixed in, it will cause abnormal high pressure in the refrigerant circulation pipeline, which is the main cause of rupture and cracks in the circulation pipeline.

(4) After the installation work is completed, please carefully confirm that there is no leakage of refrigerant. If the refrigerant leaks indoors, it will form toxic gas once it comes into contact with electric sparks from electric fans, heaters, electric stoves and other appliances.

(5) When installing one-to-multiple air conditioners, because the amount of enclosed refrigerant is relatively large, especially in small rooms, even if the refrigerant leaks, it will The concentration cannot exceed the specified value. Otherwise, it will cause hypoxia.

(6) When installing and moving the air conditioner, please implement it reliably in accordance with the requirements of the manual. When the installation is poor, it will cause abnormal operation of the refrigerant circulation pipeline, water leakage, electric shock, fire and other phenomena.

(7) Please never modify the air conditioner privately, and ask professionals to repair it. Improper repairs can also cause water leakage, electric shock, and fire.

Friendly reminder: For non-professional personnel, please do not disassemble and install by yourself to avoid refrigerant leakage, which may cause personal and property safety.

Nowadays, the adoption of air conditioner capacitor in start capacitor suppliers industry is quite common.

Hangzhou E cool refrigeration Co.,Ltd is a professional manufacturer of offering some of the best in class refrigerant gas solutions to global market. Click Arkool Refrigeration to learn more.

Deeper connections between Arkool and air conditioner capacitorare made when you go beyond the white lights of a corporate space.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect