Single head cold water machine with double head cold water machine the difference

a, single stage refrigeration system

1, the single stage refrigeration cycle is refers to the refrigerant in the refrigeration system through austerity, condensation, save, transpiration, four process is complete the cycle of single-stage chiller, which meet the intention of refrigeration. Single stage refrigeration cold water machine is a type of the machine is widely used, it can be used in fabrication, electronics, refrigeration, pharmaceutical and industrial production process, etc.

2, transpiration, single-stage tightening machine, condenser, saving valve and other affiliated equipments, etc, to each other through the pipe connection into a closed system. Among them, the transpiration is transporting equipment, the cooling capacity of liquid refrigerant transpiration after absorbing heat cooling objects to complete refrigeration; Tightening machine is the heart of the system, plays a suction, austerity, output the effect of the refrigerant vapor; Condenser will squeeze machine high temperature liquid refrigerant vapor condensation into full discharge; Save valve on refrigerant save antihypertensive effect control and regulate the province into the transpiration refrigerant liquid flow, and the system is divided into the high side and the low voltage side.

2, two-stage refrigeration system

1, the double-stage refrigeration cold water machine is developed on the basis of the single stage refrigeration cycle, the tightening process is divided into two period, from the evaporation of refrigerant in low pressure steam tight cylinder to the center of pressure, after center cooling again into the high pressure cylinder, tightening the condensing pressure into the condenser. General transpiration temperature in - 25. 7℃~- 49. 8 ℃, should adopt two-stage tightening machine for refrigeration.

2, two-stage refrigeration system by transpiration, two-stage tightening machine, condenser, central cooler, save valve and other affiliated equipments, etc, to each other through the pipe connection into a closed system. Among them, the central cooler using a liquid cooling in the center of pressure vaporization heat, cooling level low pressure discharge of superheated steam, and fell by suction temperature of high voltage level, also cools the high pressure liquid refrigerating agent together.

summing up the above, a temporary in industrial cold water machine, unipolar and multilevel refrigeration is difference: the number of stations and tightening machine, cold water machine can be divided into single-stage refrigeration and multilevel refrigeration types such as refrigerator, and multipolar refrigeration system can regulate the cooling power of cold water machine and a refrigerator.

Hangzhou E cool refrigeration Co.,Ltd's products comply fully with all compatible producing regulations.

Looking for a company to handle your refrigerant gas start capacitor suppliers? Visit Arkool Refrigeration today for more information.

Basically, you cannot have a start capacitor suppliers without having the right air conditioner capacitor. Since you are going to use it regularly, be sure to invest in one that has a high quality.

To ensure desired results, it is very essential that you get the right kind of from a certified provider..

The best way of start capacitor suppliers is to get a start capacitor suppliers refrigerant gas.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect