Simple steps and matters needing attention of refrigerant filling

When try leakage of cooling system after everything checked out, should be filling refrigerant. But the freon refrigeration system, before filling refrigerant in the system must also by vacuum drying process. Not completely dry, not filling refrigerant. Refrigerant filling method is as follows: ( 1) The refrigerant filling, first of all should be on the high side. Connection refrigerant liquid bottle and the system of charging valve, before tightening the charging valve joint, opened the door of fluid cylinder valves, rinse the impurities in the pipeline and air. ( 2) The refrigerant bottle upside down, or tilted at least thirty. Place. Best placed on the platform scale, along with the packing, constantly adjust their point of view, in order to make the liquid all net, at the same time can also be weighing filling quantity. ( 3) To the condenser and the cold storage refrigeration machine cylinder liner cooling water. ( 4) Close the dryer by-pass valve, open the dryer entrance valve, and electromagnetic valve in the conduction system. ( 5) Slightly opened the door of refrigerant cylinder valves, when the system pressure rises to 2 ~ 3 kj/cm2, check for leaks around again. ( 6) After all normal, open the refrigerator, but don't pay attention to the suction pressure is too low. Inspiratory pressure is lower than the O k/cm2, should stop the machine operation, when the pressure to start again. Should be paid attention to when using water evaporator, cooling water temperature and flow, to prevent freezing. ( 7) After filling, stop, close the charging valve and open the dryer by-pass valve, close the dryer entrance valve. In the process of filling refrigerant, drop in the temperature of the refrigerant cylinder, pressure is reduced, the available water heat booster, must not be allowed to use fire or heat with steam. On the freon refrigeration system, after filling, should be replaced immediately desiccant.

refrigerant gas are all following the most compatible manufacturing regulations.

Arkool Refrigeration has a whole range of different items to help you make an informed choice every time you make a purchase. Check it!

As the full potential of start capacitor suppliers lies in , the demand for is increasing globally, and is being adopted across the global market.

air conditioner capacitor are less complex compared with start capacitor suppliers.

If you need any help in refrigerant gas start capacitor suppliers, Hangzhou E cool refrigeration Co.,Ltd can help you. We provide the best in class. Our design and services will enable you to create the ideal room that you have always wanted!

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect