loading

One Stop Solution Service Provider for all kind of Refrigerant Gas & Motor Capacitor Products.

Screw machine refrigeration oil replacement of specific methods and steps

this paper we mainly introduce everyone to frozen oil shows the specific influence of acidification for screw machine and screw machine refrigeration oil replacement of specific methods and steps in detail. Welcome to read:

a, frozen oil acidification for the negative impact of the screw refrigeration compressor

if the inside of the screw machine lubricating oil in the acidification, will directly affect the service life of screw compressor motor. So be sure to regularly check whether frozen oil acidity is qualified, if at the time of frozen oil acidity below PH6 will have to replace the frozen oil. You also need to change regularly refrigeration system for liquid pipe of the filter drier filter, to ensure that the refrigeration system of dry;

2, screw refrigeration compressor refrigeration oil replacement method and the concrete steps of

1, the first turn on the refrigeration system of refrigerant recovery to the condenser side, then the refrigerant ruled out inside the screw compressor, and then the system Angle of the acidity of lubricating oil from the oil drain valve comes out;

2, lubricating oil in the compressor from the Angle of oil drain valve inside out, know that oil close to put out, from the high pressure end of the screw compressor detection into certain nitrogen, the joint use of nitrogen pressure to speed up the compressor lubricating oil in the discharge, know as lubricating oil row, then stop filling nitrogen, the Angle of close drain valve. Next, remove the screw compressor oil filter, and then put the tank inside of lubricating oil, and then clean the oil filter to clean after it is good to put back in fixed;

3, the next step is to compressor inside filling lubricating oil, lubricating oil must be in accordance with the amount of compressor standard listed. At the same time to take time to homework system, need to pay attention to the vacuum pump, we suggest in the high and low voltage side Angle valve or other high points, the aim is to prevent frozen within the compressor oil is pumped into the vacuum pump to cause damage to it; After job completion to the system of vacuum pressure or at the time of leak, must observe pressure if there is a big fluctuations or rebound;

4, at the time of filling oil, can be used to clean plastic pipe connected to the oil drain valve, the other end of the plastic pipe into the barrel inside, at the time of filling oil cans to seal up, reduce the air pollution of oil itself.

this of screw refrigeration compressor refrigeration oil to replace the specific steps to introduce here!

Collectively, the effect of refrigerant gas on industrial society has been to eliminate start capacitor suppliers and drastically reduce the time long associated with start capacitor suppliers.

To know more about air conditioner capacitor, please check our website at Arkool Refrigeration.

For most children start capacitor suppliers is a struggle. If that is also the case for your children, find the solution at Arkool Refrigeration.Arkool are your best choice.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect