Run capacitor and motor start capacitor, respectively, have what effect?

As is known to all, not like a three-phase motor, single-phase ac motor to power it will turn up, it requires a startup torque to rotate, and the torque of the chronological and determines the steering of the motor, start the way is very much also, the capacitor start is a kind of, customarily call starting capacitance, single-phase motor it is needed to turn up smoothly.

but not only a single-phase motor capacitor, some motor with two capacitors, is this why? Because of some motor it is configured with a startup capacitor and a capacitor operation, how to return a responsibility?

run capacitor: it is to put the alternating current phase shift after each winding access to form an alternating magnetic field, and with the primary winding of the alternating magnetic field to form an approximate circle of elliptic rotating magnetic field. So he can be the same capacity, but its role is different.

whatever the capacitor, at the beginning of the motor starting has a starting role. But when the motor reaches the rated speed 75 [ %) Or so, only by the centrifugal switch automatically disconnect starting capacitance, while with the motor running capacitor continue to work. The motor starting process, it is & other; Column & throughout; In the process. For single-phase and three-phase motor, no phase difference, produce a rotating magnetic field. Capacitance effect, is to make the motor starting winding currents in time and space, running ahead of winding 90 electrical point of view, form the phase difference. Among them, the running capacitor also to play the role of a balance between the deputy winding current. Starting capacitor is the job of the instantaneous short, pressure requirements in more than 250 v, and running capacitor should have been working for a long time, required pressure above 450 v.

start capacitance is to make the individual motor start coil electricity at startup, starts to cut off, and in running capacitor is to make the motor run capacitor compensation, so start capacitance cannot little, and capacitance can need not operation.

when running capacitor is the normal work of the compressor with the launch of the capacitance is compressor startup and running up a piece of the compressor. Press turn up after startup capacitor is disconnected. Run and start capacitance and together but start capacitance has a past, turn up starting capacitance is useless.

in the end, start and run capacitors difference in where? Large capacity, is to start capacitance is generally run capacitor 2 - Five times, and running capacitor capacity is small, the capacity difference is big, easy to difference.

To be the best worldwide provider of higher-value air conditioner capacitor and the center for quality employment opportunities.

Our mission is to operate the best specialty retail business in domestic, regardless of the product we sell. Because the product we sell is refrigerant gas, our aspirations must be consistent with the promise and the ideals of the volumes which line our manufacture.

Individuals with varied technical skills use air conditioner capacitor in a wide range of applications.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect