loading

One Stop Solution Service Provider for all kind of Refrigerant Gas & Motor Capacitor Products.

Related matters needing attention of using refrigerant r404a _

For domestic environmental protection refrigerants development and the use of constant pace again, also gradually appear some environmental protection refrigerants in refrigeration market, is a kind of environmental protection refrigerants, refrigerant r404a environmental protection refrigerant R404a as a substitute for R22, one of the cooling performance of the two is similar, but also need to pay attention to several problems in the process of replacement. R404A replace R22 need to pay attention on the physical properties: 1, the use of alternative refrigerant R22 as refrigerant R404A lubricating oil, must be used PVE ester oil to replace R22 with mineral oil. 2, the exhaust pressure of refrigerant R404A is about 1 of R22. 2 times, mass flow rate is 1 of R22. About five times, exhaust velocity increases, the resistance increased. Condenser, in general, the change of heat capacity than R22 increased 20% ~ 30%. Dupont, at the same temperature and the saturation pressure of refrigerant R22 as refrigerant R404A is different, so the R404A institution and R22 different thermodynamic expansion valve movement. 3, due to the saturation pressure is higher than R22 refrigerant R404A, so the pressure vessel design pressure to make changes in the system. 4, R404A are azeotropic mixed working medium, non azeotropic mixture composition concentration changes with the temperature, pressure, the production of refrigeration system, debugging and maintenance has brought certain difficulties, the heat transfer performance of the system is also can produce certain effect, especially when the refrigerant leakage, all system refrigerant needs emptying displacement, so as to guarantee the proportion of each blend components, and to achieve design refrigeration effect, otherwise it will get worse and worse. 5, because refrigerant R404A and lubricating oil has nothing to do with the intermiscibility of water is very good, so the system of water and residue, cleanliness requirements such as compared with R22 refrigerant are improved, R404A moisture control and impurities control system is a more important indicator, corresponding filter unit in the system, etc. To make changes. Above about the related introduction of refrigerant R404A over here, hope to bring you some help.

Hangzhou E cool refrigeration Co.,Ltd has created its reputation on a commitment to manufacturing high-quality products and services while satisfy the needs of customers.

Hangzhou E cool refrigeration Co.,Ltd’s sole aim is to provide exquisite and unheard of features to the concept of producing technology.

Hangzhou E cool refrigeration Co.,Ltd believes that the average profitability will be sufficient.

With this competency, Hangzhou E cool refrigeration Co.,Ltd provide high technology and assist customers to create added value and contribute to the development of producing refrigerant gas.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect