Refrigerant safety level and safety standard

1. National standards for refrigerant numbers and safety levels

The National Bureau of Quality and Technical Supervision of the People’s Republic of China issued GB/T7778- on January 10, 2001. 2001 'Refrigerant Numbering Method and Safety ClassificationIt was later revised into GB/T7778-2008 'Refrigerant Numbering Method and Safety Classification'.

From the perspective of standards, Europe, America and Japan have allowed low flammable or flammable substances to be used as refrigerants under certain circumstances. The promulgation and implementation of standards such as ISO 817-2014, ISO 5149-2014, ASHRAE-34-2014 and AHRI 700-2015 have promoted the application and promotion of flammable refrigerants.

In the latest revision of GB/T 7778, referring to ANSI/ASHRAE 34-2014, based on toxicity and flammability, refrigerants are divided into A1, B1, A2L, There are 8 categories of B2L, A2, B2, A3 and B3, and the refrigerant numbering method and safety classification standard are unified with the main international standards.

2. Refrigerant safety level

The safety of refrigerant mainly refers to the toxicity, flammability and Explosive. The safety level of refrigerant is represented by A, B, C plus 1, 2, 3, A1 is the safest, and C3 is the most dangerous. Substances with safety level C (C1, C2, C3) generally cannot be used as refrigerants.

The safety levels of common refrigerants are as follows:

Class A1:

R11, R12, R13, R113, R114, R115, R116, R22, R124, R23, R125, R134a, R227ea, R236fa, R1233zd(E), R1336mzz(Z), R218, RC318, R401a, R401b, R402a, R402b, R403a, R403b, r404a, R407a, R407b, R407c, R407d, R408a, R409a, r410a, R417a, R422d, R500, R501, R502, R507a, R508a, R508b, R509a, R513a, R744

A2 category:

R142b, R152a, R406a, R411a, R411b, R412a, R413a, R415b, R418a, R419a, R512a

A2L category:< /p>

R143a, R32, R1234yf, R1234ze(E)

Class A3:

R290, R600, R600a, R601a, R1270, RE170, R510a, R511a

Class B1: R123, R245fa

Class B2L: R717

3. Standards for the safety requirements of refrigerant application in mechanical refrigeration systems for refrigeration and heating

Safety of mechanical refrigeration systems for refrigeration and heating in China GB9237-2001 'Safety and Environmental Requirements for Refrigeration Systems and Heat Pumps' is required, which is equivalent to the ISO5149-1993 standard. There are strict restrictions on R170, 290, 600a, 1150, and 1270, which are mandatory standards. This standard is applicable to various refrigeration systems and specifies safety requirements related to the design, manufacture, installation and operation of refrigeration systems. The standard stipulates that the use of flammable refrigerants of A2 and A3 such as HFC32 and HC290 in human comfort air-conditioning systems is prohibited.

In the recent revision of GB9237 'Safety and Environmental Requirements for Refrigeration Systems and Heat PumpsAgent application. When ventilation measures are not taken, the maximum charge volume and room volume requirements are specified, and calculation formulas are given; when ventilation, safety valves and other measures are taken, the charge volume of refrigerant can be enlarged.

Many of us have heard about refrigerant gas and seen some of these units in operation in start capacitor suppliers, start capacitor suppliers and start capacitor suppliers spaces.

If you're interested in buying a of high quality and affordable price, let Hangzhou E cool refrigeration Co.,Ltd at Arkool Refrigeration be your guide to the best shopping experience.

Hangzhou E cool refrigeration Co.,Ltd needs to ensure we're resolving customer issues as quickly as possible. By doing so, it leads to positive customer experiences and brand loyalty.

As a top provider of products, Hangzhou E cool refrigeration Co.,Ltd will surely meet your urgent need for air conditioner capacitor solutions. Go to Arkool Refrigeration.

Hangzhou E cool refrigeration Co.,Ltd, which contributes itself on refrigerant gas for creating more useful application.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect