Refrigerant R410A air conditioning refrigerant method and key points of maintenance

add refrigerant refrigerant r410a air conditioning method and maintenance points you to understand? Don't understand it doesn't matter, here small make up for everyone to do the introduction, let's get together and see it.

1, confirm the name of air conditioning refrigerant before operation, and then to the operation of the different refrigerant implementation, using R410A refrigerant must not use the refrigerant R410A refrigerant.

2. Be sure to check before add refrigerant funnelled to deal with again after funnelled add refrigerant, note: it is prohibited to use air or cold media crackdown leak detection.

3, R410A refrigerant is an analog azeotropic mixture refrigerant, when add refrigerant, ensure to add refrigerant liquid way.

4, R410A refrigerant leakage after add refrigerant has the following five kinds of methods, details are as follows:

method one:

remote control into the rated cooling mode, the refrigeration compressor opens the mode of case: the remote set temperature of 17 ℃; The remote control set high winds of the wind; 10 seconds press strong 6 consecutive ( Or more than six times) , after 10 seconds to 10 seconds (long tone of the buzzer rang The music of the buzzer ringing up) , enter the rated refrigerating test run. Compressor operation frequency fixed rated test frequency, indoor and outdoor fan wind speed fixed to the rated wind speed test.

method 2:

enter the rated refrigerating mode with the remote control with beautiful small plate test, check the exhaust temperature, exhaust temperature in 75 - 80 ℃ is more appropriate.

method 3:

in open test small plate, cooling mode using the beauty view to temperature and indoor temperature tube temperature, add refrigerant, T = T tube + back ( 1 - 3) ℃

method 4:

enter the rated refrigerating mode with the remote control, wind turbine within 20 minutes or more, observe evaporator for homogeneous condensation state, back to the trachea homogeneous condensation.

note: the above methods are in the external environment temperature above 0 degrees to complete. 5:

method

under the external environment temperature is below freezing, must adopt the way of quantitative add refrigerant add refrigerant. Ambient temperature is lower than - in the outside world 10 try to persuade the customer not to use air conditioning, air conditioning maintenance as far as possible before the rise of temperature of the spring season for repair.

the above introduction about the R410A refrigerant to the over here, hope to be able to bring you some help, if you have a demand on refrigerant R410A, welcome consultation discussion with us, we wholeheartedly at your service.

In an age when refrigerant gas is increasingly important, the researchers believe manufacturers should pay close attention to their results.

Hangzhou E cool refrigeration Co.,Ltd serves a wide variety of professional markets and industries across the globe. Contact us at Arkool Refrigeration to find the you have always dreamt of.

We are proud to be a part of helping you to make healthy choices to last a lifetime. Check out our website to see all start capacitor suppliers air conditioner capacitor products we offer at Arkool Refrigeration. If you want to start that road to be better, contact us today!

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect