R410A higher than the pressure of refrigerant R22 about 1. Six times or so, so, in the process of construction and after-sales service in case of wrong operation, is likely to be a major accident. When installing a r410a refrigerant air conditioning, using R410A special tools and materials, pay attention to the operation.
1, before installation, first to make sure of the name of air conditioning refrigerant, and then implement different operations for different refrigerant,
in the use of the household of refrigerant R410A air conditioning, must not use the refrigerant R410A.
in the use of refrigerant R22 air conditioner, must not be used as refrigerant R410A.
2. If there is leakage of refrigerant in the operation, ventilation is carried out in a timely manner, please.
3, when install or mobile air conditioning, please don't to outside air mixed with air conditioning refrigerant R410A refrigerant circulation line.
if mixed with air and non-condensable gas, will lead to abnormal high pressure refrigerant circulation pipeline, the circulation line is the main cause of fracture, crack.
4, after the installation work, please confirm carefully, there can be no refrigerant leakage phenomenon.
if the refrigerant leakage in indoor, once with the electric fan, heating furnace, electric appliance, sparks of toxic gases will form.
5, when installing a yituo more air conditioning, due to the volume of the refrigerant sealed more, especially in the small room for installation, even one thousand refrigerant leakage occurs, its concentration cannot exceed the specified value. Otherwise, will cause the phenomenon of hypoxia.
6, when install or mobile air conditioning, please according to the requirements of specification and reliable.
when improper installation will cause refrigerant circulation line work is not normal, water leakage, electric shock, fire wait for a phenomenon.
7, do not secretly to air conditioning, please professional personnel for repair. Repair improper will cause water leakage, electric shock, also cause fire wait for a phenomenon.
the above introduction about the R410A refrigerant to the over here, hope to be able to bring you some help, if you have a demand on refrigerant, welcome consultation discussion with us, we wholeheartedly at your service.
The use and installation of refrigerant gas is compared with most other systems for managing the start capacitor suppliers effectively and no doubt air conditioner capacitor have won the race so many times.
have become more diverse in appearance and function thanks to the advanced technology. Choose a that you can trust to deliver an excellent user experience reliable performance at Arkool Refrigeration.
For Hangzhou E cool refrigeration Co.,Ltd as a whole to adopt an attitude of acceptance toward change and technological innovation, we first have to truly embrace it and practice what they preach. Technological development needs to be more than just another investment, but a complete integration.