Refrigerant filling method of water-cooled screw chiller

  【】The refrigerant plays a vital role in refrigeration equipment. This is something that everyone in this industry needs to understand. What are the refrigerant charging methods for water-cooled screw chillers? Let’s take a look with the editor today!

   Generally, refrigerants can be divided into five categories according to their chemical composition:

  1, Freon;

  2, unsaturated hydrocarbon refrigerants ;

  3, saturated hydrocarbon refrigerant;

  4, inorganic compound refrigerant;

  5, azeotropic refrigerant. In these five categories, water-cooled screw chillers usually use R-22 type refrigerant, and the chemical composition is difluoro-chloromethane. Mainly used in medium and low temperature commercial refrigeration, catering refrigeration, supermarket display cabinets, residential and commercial air conditioning systems.

What are the filling methods of    water-cooled screw chiller refrigerant?

After the    refrigeration system has been strictly tested without leakage, the refrigerant can be charged. There are two ways to charge refrigerant:

   1. Filling from the bypass hole of the compressor discharge valve

   is to inject Freon liquid directly into the system. Its advantage is that the filling speed is fast and safe, and it is suitable for the situation that there is no refrigerant in the system and the vacuum has been evacuated, that is, it is suitable for s* times of filling. It relies on the pressure difference and height difference between the freon in the cylinder and the system to discharge into the system by itself. If you use this method to infuse freon steam. The injection volume is very small, and only when the liquid is injected can it be injected more and quickly. Moreover, the freon in the bottle is not completely filled. When the pressure in the system is higher than 3KG/MC2, the filling on the high-pressure side should be stopped. If the filling volume is insufficient, it can be filled from the suction side. When filling freon from the high-pressure side, Never start the compressor to avoid accidents.

  2. Filling from the compressor suction valve bypass hole

   Filling freon gas from the low pressure side of the compressor, start the compressor and do not inject liquid refrigerant to avoid the machine Liquid hammer occurred. This method is suitable for the situation that the system is insufficient and needs to be refilled. In our country's general commercial or canteen, the small Freon refrigeration system is usually in the form of a unit, and most of the high-pressure parts are filled with Freon in the manufacturing plant. Therefore, most small Freon devices need to be supplemented with refrigerant. Through the above detailed explanation, let us know what are the refrigerant filling methods of water-cooled screw chillers. We can make corresponding choices based on some real problems, which will not only improve our work ability, but also Let us operate the machine very smoothly.

If you are looking to get started with refrigerant gas, it's important to find a quified . Let Hangzhou E cool refrigeration Co.,Ltd be your provider. Visit us at Arkool Refrigeration.

For more information please see our site at Arkool Refrigeration. Don't be hesitate to contact us!

Hangzhou E cool refrigeration Co.,Ltd provides the ideal conditions for business creation – access to cash, human capital and affordable office space, for instance – can help new ventures not only take off but also thrive.

What Hangzhou E cool refrigeration Co.,Ltd discovered was that innovation occurs when business models match up with one or more of the air conditioner capacitor where technological advances overlap with market needs, thus resulting in growth and transformation.

Hangzhou E cool refrigeration Co.,Ltd knew if this worked for us, it would work for others, so we took the exclusive product and program and re-developed it to be more accessible to customers.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect