Refrigerant addition method for refrigerator freezer

The steps of adding refrigerant to refrigerators are as follows: 1. When adding refrigerator refrigerant, ensure that the system has been shut down, and then connect the system; 2. When connecting the system, close the high and low pressure valves and turn the system off. The high and low pressure test connections are locked at the same time, and the vacuum pump connection of the filling interface is tightened at the same time; 3. When the system is vacuumed, the high and low pressure valve must be opened first, then the system starts to evacuate, and after a period of time, check whether the system is The vacuum is complete, then close the high and low pressure valves, and finally turn off the vacuum pump; 4. Disconnect the connection between the yellow tube and the vacuum pump when adding refrigerant, and then connect it to the refrigerant bottle and tighten it; 5. At this time First open the refrigerant bottle, then open the valve core on the meter group to exhaust the air in the yellow tube, then turn the refrigerant bottle upside down and put it away at the same time; 6. Open the high and low pressure valve, add refrigerant to the system, and wait until the specified amount is reached After that, close the high and low pressure valves and put the refrigerant bottle in place.

To judge whether the amount of refrigerant added is in place, please check according to the following steps: The method of adding refrigerant to refrigerators and freezers is as follows: Method 1: 1. Connect the filling pipe to the compressor If the process port is connected, vacuum first, and the evacuation time is determined according to the condition of disconnecting the process port during maintenance. If there is residual gas at the broken process port, the evacuation time is 5-10 minutes; if there is no residual gas from the broken process port, it should be evacuated for 20-30 minutes. After 5 minutes of vacuum, the compressor should be started at the same time, and the compressor should be stopped for 3 to 5 minutes. 2. After the vacuum is completed, first close the maintenance valve and then stop the vacuum pump, quickly connect the filling pipe to the fluorine bottle, and open the fluorine bottle valve. According to your own habits, you can put the fluorine bottle upside down or upright. Slightly loosen the connecting port of the filling pipe of the half-turn repair valve, use fluorine pressure to overflow the air in this section of the filling pipe (usually called 'washing pipe'), and tighten the connecting port after about 2 to 3 seconds. 3. First use the pressure difference after the vacuum to stop and refill. Open the maintenance filling valve for about 1/4 turn, close the filling valve after 5-6 seconds, wait another 2 minutes and then start the compressor. At this time, the low pressure gauge will drop rapidly. If the needle will directly point below 0, it means that the filling volume is not enough, you can slightly open the filling valve to replenish; if the pressure is below 1 kg, you can let the refrigerator continue to run the test machine. In the test machine, observe the frosting of the evaporator in the box, feel the heat dissipation of the condenser, and the temperature of the return air pipe. If there is frost in the return pipe, open the filling valve several times and let it go until no frost is formed. If it is found that the pressure gradually reaches negative pressure and the compressor has a dull sound, it means that the ice block has occurred, and it should be dealt with separately according to the solution of the ice block. 4. About half an hour after the test machine observation, the evaporator should be fully frosted, the heat dissipation of the condenser is normal, and the air return pipe will gradually cool down to a little condensation, and it can automatically stop after 1 hour. The regularity of starting and stopping is normal, and the whole liquid is added. The process and the amount of liquid added can be regarded as complete and appropriate.

Method two: 1. Connect the vacuum pump to vacuum for about 10 minutes (depending on the specific situation), turn on the refrigerator and freezer compressor after 5 minutes (the vacuum pump at this time) Cannot stop), turn off the vacuum pump after 10 minutes, the compressor is still running. Connect the fluorine bottle (to ensure the quality of fluorine), and use the fluorine in the fluorine bottle to overflow the air in the filling pipe. Temporarily close the filling valve, fully open the fluorine bottle valve, turn the fluorine bottle upside down, and open the filling valve a little bit (about half a circle). At this time, start adding fluoride to the refrigerator and freezer. Close the door or cover the box. 2. It can be seen from the whole process that the high and low pressure gauges are basically ignored, no matter what! The temperature of the compressor and the current do not look at it, no matter what! Regardless of the amount of frosting and fluoride! ! ! The pressure gauge is only used to observe whether the system is blocked. Note that the pressure during fluorine addition should not be too high to avoid shutdown of the overload protection. As long as the fluorine operation is performed properly and the compressor has no 'congenital failure

3. In the end, don't let the return pipe outside the box frost, only condensation; measure the current of the compressor not to exceed the rated value; it should be able to automatically stop normally after running for about 2 hours. Regardless of other things, the seal is over.

Method 3: According to the marked amount on the back of the refrigerator nameplate, use an electronic scale to fill in according to the marked amount, and then judge whether the refrigerator starts and stops normally according to the above method.

The average consumer is always looking for ways to save money while finding out solutions, is designed for killing two birds with one stone, providing a perfect solution to air conditioner capacitor problems.

With continuous operational improvements, expanding capacity and a strong competitive position for serving strategic domestic markets, Hangzhou E cool refrigeration Co.,Ltd are positioned for long-term growth that will benefit our customers and investors.

To ensure desired results, it is very essential that you get the right kind of from a certified provider..

Producing with varied technical skills, refrigerant gas can be used in a wide range of applications as start capacitor suppliers.

Hangzhou E cool refrigeration Co.,Ltd has been focusing on reaching the ideal profits.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect