loading

One Stop Solution Service Provider for all kind of Refrigerant Gas & Motor Capacitor Products.

Reading: industrial cold water machine refrigerant cycle system

< p > cold water machine the refrigerant cycle system of liquid refrigerant in the evaporator absorbs the heat in the water and began to evaporate, the ultimate formed certain temperature difference between refrigerant and water, liquid refrigerant also completely evaporate into a gas compressor suction and after compression, gaseous refrigerant absorbs heat through the condenser, condensed into liquid, through the thermal expansion valve throttle into low temperature low pressure refrigerant entering the evaporator, after completing the process of refrigerant cycle. < / p > < p > cold water machine molding products, due to the varieties of raw materials, molding products area size and shape is different, need the clamping force is also different, when moving mold please the minimum clamping force adjustment according to the actual needs. In this way, can save the electricity consumption and will significantly extend the service life of the machine. < / p > < p > industrial cold water machine will be pay attention to the safety of the operation, when the machine is used for each operation to check the safety device of the machine, insurance plunger and the reliability of the safety door. In the process of the machine, remember not to dig its hand deeper into the clamping mechanism. When get products, be sure to open the door, after confirm there is no foreign body in the personnel safety and mould, to close the door. In addition, in the running hand cannot stretch between the nozzle and the mold gate. When repairing the mold, please close the oil pump motor. < / p > < p > screw cold water machine high efficient and good performance, low noise, small vibration, energy saving, high reliability, long life, etc. According to customer needs and cold tonnage size, using single or multiple units. Compressor can be in accordance with the load change, automatic alternating regulated, and balance the compressor running hours, greatly extend the use of water chillers. < / p > < p > < / p >

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect