R404a replace R22 refrigerant issue to consider

at present, the domestic refrigerant industry throw is the most widely used refrigerant R22, but due to the damage to the ozone layer and the higher the greenhouse effect, our country in accordance with the relevant international agreed to determine the save for a rainy day refrigerating products manufacturers, has begun to gradually accept and use new HFC green environmental protection, such as the substitute for R22R r404a refrigerants, but in actual use, there are many differences must pay attention to both. In order to help you better use of HFC green new environmental protection refrigerants, now in the piston compressor refrigeration system using R404A refrigerant the author analyzes some problems to be pay attention to

1. Using R404A replace R22 smooth oil problem is the biggest problem, it is necessary to form a complete set USES PVE ester oil smooth replace R22 with mineral oil. Esters smooth high affinity of oil and water, dehydration nature difference, it should be used in the as far as possible in order to prevent air touch with the outside world, the container after opening, should use as soon as possible, after use shall be kept sealed; Away from the oxidant, strong alkali, strong acid, preserved in good ventilation advantages; When using, should prevent touch skin and eyes, prevent the steam inhalation and spray. 2. The exhaust pressure of refrigerant R404A is about 1 of R22. 2 times, mass flow rate is 1 of R22. Around 5 times, add exhaust velocity, resistance increased. Condenser, in general, the change of heat capacity than R22 increased 20% ~ 30%. 3. Same temperature R404A and R22 saturation pressure is different, so the R404A and R22 thermodynamic expansion valve action organization. Together for refrigerant R404A and smooth oil sealing material intermiscibility, expansion valve sealing material will change accordingly, so, on the thermal expansion valve selection should choose R404A dedicated expansion valve. 4. Because of saturation pressure is higher than R22 refrigerant R404A, so the system pressure container plan to make changes, to ensure safety. Such as accumulator and gas-liquid separator, etc. System parts together on the relief valve and fusible plug setting of the device will be changed. Because in the same conditions of displacement, R404A gas density is about 50% larger than that of R22, so when using R404A refrigerant piping plan, selection of pipe diameter than the R22. 5. The same compressor, using R404A current than R22, so the communication of the compressor touch device, thermal relay, and cable wire diameter to adjust. In the aspect of system maintenance, high pressure switch Settings by 2. 45 mpa is adjusted for 2. 7MPa。 6. Since 404 a saturation pressure and R22 is different, so the air tightness test pressure than R22. Vacuum system should be higher than that of R22, moisture content is lower than R22. To with liquid refrigerant filling type filling, in case of R404A configuration change. 7. Azeotropic mixed working medium R404A right and wrong, non azeotropic mixture composition concentration change with temperature, pressure and change, the production of refrigeration system, debugging and repair are surely bring difficulties, impact on system heat transfer function will occur, must, especially when the refrigerant leakage, all emptying system refrigerant demand substitution, such ability ensure the mixture fraction, and cooling ability to planning, otherwise it will get worse and worse. Because refrigerant R404A and smooth intermiscibility of oil and water is very good, so the system of water and residue, and cleanliness requirements such as compared with R22 refrigerant are improved, R404A water control system and impurities control is an important indicator of system to change the corresponding filter equipment, etc.

,

more information about reading http:///

tag: & nbsp  & NBSP air conditioning refrigerant & NBSP refrigerator refrigerant

Arkool allocates customer service resources to the platform where their customers are most vocal.

Hangzhou E cool refrigeration Co.,Ltd aims to hire several additional experienced marketing professionals that can add to our existing talent-pool and help continue the steady growth of our business.

Hangzhou E cool refrigeration Co.,Ltd knew if this worked for us, it would work for others, so we took the exclusive product and program and re-developed it to be more accessible to customers.

The unique connections between air conditioner capacitormanufacturing and customers happen when you find ways to relate on a more personal and engaging level that goes beyond a product.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect