Procurement of refrigerant to know the difference of the refrigerant R22 and R410A

purchase refrigerant to know the difference of the refrigerant R22 and r410a, why say so, chemical below small make up for everyone to do the introduction, let's learn together.

with the phasing out of refrigerant R22, R410A refrigerant using range is more and more big, the refrigeration, many friends asked whether R22 directly replace R410A in dispatching system, which is unreasonable. Two kinds of refrigerant different physical and chemical parameters, the differences in system design, need to pay attention to.

the difference of the refrigerant R22 and R410A

1, R410A refrigerant requires a synthetic refrigeration oil ( POE) , due to the high hygroscopicity, POE oil prone to hydrolysis, relative to R22, R410A system more strict with moisture moisture content.

2, perfusion after reducing heat exchanger structure, R410A system relative R22 perfusion to decrease about 20% ~ 30%. Bigger than R22, R410A system of total heat transfer characteristics of heat transfer efficiency is high, the heat exchanger can be miniaturized.

3, R410A for HFC - 32 ( R32) And HFC - 125 mixture refrigerant R410A for copper tube is more demanding, and R22 can use normal brass; R410A operation pressure is higher than R22 50 ~ 70%, about 1. 6 times.

4, R410A belongs to low toxicity, no combustion propagation, does not destroy the ozone layer, R22 is fatal for ozone destruction; R410A system refrigeration capacity, better if R22 refrigeration capacity 100%, R410A refrigeration capacity 147%;

5, even R410A does not destroy the ozone layer, but can produce greenhouse gases, the effect of greenhouse gases produced by the even greater than the R22.

6 is larger than that of R22, R410A vapor density is big, so R410A steam flow rate compared with R22 slow about 30%; R410A is more soluble than R22. When particles floating in R410A, can smoothly circulate in the system.

more about the difference of the refrigerant R22 and R410A over here, hope to be able to bring you some help, if you have a demand on refrigerant, welcome consultation discussion with us, we wholeheartedly at your service.

Hangzhou E cool refrigeration Co.,Ltd highlighted the need to foster a human openness to technological innovation.

Are you looking for ? Hangzhou E cool refrigeration Co.,Ltd has the collection you want, like start capacitor suppliers or start capacitor suppliers and many more in the online stores. Visit Arkool Refrigeration to know more.

Hangzhou E cool refrigeration Co.,Ltd understands how essential it is to offer ample options, such as air conditioner capacitorstart capacitor suppliers to afford high-quality products for customers.

Though the cost of these sustainability initiatives as refrigerant gas can be high, harnessing the power of an ethical supply chain to appeal to conscientious consumers can be a smart move both ethically and financially.

We create a group of experts to promote the quality standard and innovative technology of air conditioner capacitor.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect