Precautions when handling industrial chiller refrigerant

  【】Precautions when handling industrial chiller refrigerant

   1. Before starting the chiller refrigeration compressor to pump the refrigerant. The pressure relay on the refrigeration compressor control circuit should be connected to the oil The differential pressure relay contacts are short-circuited. Otherwise, when the oil pressure difference or low pressure is low during pumping, the refrigeration compressor will automatically stop, which will affect the refrigerant processing work. However, when the refrigeration compressor is running, since the refrigeration compressor has been cancelled, the change in oil pressure should be tightly injected to prevent the refrigeration compressor from running out of oil. At the same time, the temperature and pressure changes of the refrigeration compressor should be noted. If these parameters are abnormal, the cause should be found out, and the work should be started after troubleshooting.

  2. Before the whole system is evacuated, all valves except the wide door to the atmosphere should be opened. Especially for the nitrogen system, no blind spots should be left to prevent the damage caused by nitrogen during maintenance.

  3. The low-pressure equipment of the industrial chiller has a low environmental temperature and a thick thermal insulation layer. It has a good protective effect, and the internal refrigeration is slow. You can take corresponding measures to increase the cooling temperature to promote the refrigerant Yanfa as soon as possible.

  4. When the system discharges residual nitrogen, do not open the valve too large. Use enough water to dilute and dissolve the atmosphere. In addition, after the residual nitrogen is discharged, all valves connected to the atmosphere should be opened, and the equipment can be overhauled after the nitrogen concentration drops.

   5. If the equipment and system are overhauled due to leakage. When using the refrigeration compressor of the refrigerator to suck refrigerant, pay attention to the suction pressure not to be too low, and it is advisable to stop the machine when it is close.

Hangzhou E cool refrigeration Co.,Ltd works very hard to understand your objectives, then create a program that can help you meet them.

We are proud to be one of the largest suppliers out there. You will love what we offer for your air conditioner capacitor solution. Check our website at Arkool Refrigeration or call to talk to our customer service department with any questions you may have.

Hangzhou E cool refrigeration Co.,Ltd provides the ideal conditions for business creation – access to cash, human capital and affordable office space, for instance – can help new ventures not only take off but also thrive.

There are many advantages associated with .

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect