loading

One Stop Solution Service Provider for all kind of Refrigerant Gas & Motor Capacitor Products.

Precautions for overhaul of refrigeration system of refrigerators using R600a refrigerant

1. Maintenance site:

Smoking is strictly prohibited; equipped with fire-fighting equipment, well ventilated; equipped with leak detector/R600a sensor (if conditions permit); R600a special exhaust equipment should be provided, which must be turned on when working , Because R600a is heavier than air, the exhaust vent must be located close to the ground; ventilation equipment and electrical appliances in the site should be explosion-proof; there should be no grooves and pits in the site; the site should have fire protection signs.

2. Maintenance equipment:

The R600a storage tank should be placed separately in an environment of -10~50°C, well ventilated, and a warning label should be attached; the leak detection equipment must ensure that it can It is used for R600a refrigerant; R600a refrigerator must use special explosion-proof vacuum pump and charging equipment. Because of the different lubricating oil (R134a refrigerator uses lipid oil, R600a refrigerator uses mineral oil), it is not allowed to mix with R134a refrigerator maintenance equipment; The charge volume of R600a refrigerator is only 40-50% of that of R134a refrigerator, so the vacuuming and filling equipment of refrigerator should ensure certain accuracy, the vacuum degree should be less than 10pa, and the filling volume deviation should be less than 1g; R600a maintenance tools and refrigeration The maintenance tools in contact with the agent should be stored and used separately, and should not be mixed with the maintenance tools of the R134a refrigerator.

3. Maintenance technology:

It is not allowed to open the refrigeration system in the user’s home; the type of refrigerant should be determined from the compressor’s nameplate before the refrigerator is repaired; because R600a refrigerant affects lubricating oil In addition to its strong solubility, coupled with its low pressure, the low pressure side of the refrigerator is usually negative when the refrigerator is working. Therefore, before repairing and welding the refrigeration system, ensure that the R600a in the system is discharged cleanly. Usually, the high and low pressure process pipes should be opened first to discharge. Then use the R600a special vacuum pump to evacuate the high and low pressure sides, while gently shaking the compressor by hand; if the compressor is replaced, the charge volume is the nominal value on the refrigerator parameter plate, if the compressor is not replaced, the charge volume is the nominal value 90% of the value; no open flame should be used for the system seal, ultrasonic welding or lock ring can be used; the nozzle of the replaced compressor must be sealed; because the R600a refrigerator is working, the low pressure side is negative pressure, so the refrigerator should be stopped during leak detection ; The temperature controller and light switch of the refrigerator compartment of R600a refrigerator are not in contact with the refrigerant, and can be used in common with R134a refrigerator; the desiccant used in R600a refrigerator is the same as that in 134a refrigerator, and the drying filter can be used in common (only unused new drying filter The solenoid valve of the R600a dual-capillary refrigerator must be explosion-proof and cannot be mixed with the R134a refrigerator.

Hangzhou E cool refrigeration Co.,Ltd has an array of branches in domestic for munufacturing air conditioner capacitor.

Hangzhou E cool refrigeration Co.,Ltd’s purpose is to create superior value for our customers, employees, communities and investors through the production, conversion, delivery and sale of energy and energy services.

Hangzhou E cool refrigeration Co.,Ltd's main technology of refrigerant gas leads us to understand and utilize information correctly.

Hangzhou E cool refrigeration Co.,Ltd prepares for every aspect of running a business, and this includes developing a sound understanding and ability to manage the financial aspects of our company, including financial analysis, taxes and budgeting.

The key to air conditioner capacitor is understanding where there is a problem or need in certain markets and knowing how to solve it.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect