Precautions for charging refrigerant

At present, some air conditioners use non-azeotropic refrigerants such as r404a, R407c, r410a, etc., and these refrigerants must be filled with liquid. Due to the different properties and boiling points of each component of the non-azeotropic mixed refrigerant, the gas and liquid components of the non-azeotropic mixed refrigerant are different, and filling with gas will cause the composition of the refrigerant to be charged to deviate. Of course, if a tank of refrigerant is completely charged into a machine, there is no such problem.

1. Non-azeotropic refrigerant must be filled with liquid

If it is a single refrigerant such as R22 or azeotropic refrigerant such as R507, It can be filled with gas or liquid. 2. Prevent liquid shock The so-called 'liquid shock' refers to the refrigerant liquid being sucked in by the compressor, causing an abnormal shock accident to the compressor. Simply put, gas is compressible, while liquid is incompressible. When liquid refrigerant in the refrigeration system enters the compressor cylinder, it will impact the compressor valve plate, causing damage to the valve plate and other components. The most serious consequence is that it may cause permanent damage to the compressor. Liquid hammer mainly occurs in piston compressors. Too much refrigerant or lubricating oil in the system, excessive adjustment (opening) of the expansion valve (or regulating valve), and unstable heat load (heat transfer) of the evaporator may cause liquid shock. Adding liquid too fast in the process of charging refrigerant is one of the important reasons for liquid hammer. If the compressor has abnormal shock (knocking or impact) sound during charging, or accompanied by strong rocking vibration, it means that liquid shock has occurred. A slight and short-term abnormal impact may not be a big problem, but frequent long-term and heavy liquid strikes can deform the compressor, rupture or even break the valve, and directly damage the compressor.

There is a strong need for more research on , in order to be able to provide strong and conclusive evidence of their start capacitor suppliers effects. However, recent studies have provided valuable insights into how the intake of may result in improved start capacitor suppliers.

The best for start capacitor suppliers is one that works best for your needs and what you can support in your home. Among Hangzhou E cool refrigeration Co.,Ltd's diversified list of products at different price ranges, you will surely find your one with high quality. make your choice at Arkool Refrigeration!

With its quality certified and recognised by professional intitutions and customers, Hangzhou E cool refrigeration Co.,Ltd is one of the leading providers in China.

It is never too late to have a new mindset and to get things moving in the right direction. Choose Hangzhou E cool refrigeration Co.,Ltd to be your quality provider.

air conditioner capacitor allows users to apply in different ways for satisfying their needs.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect