loading

One Stop Solution Service Provider for all kind of Refrigerant Gas & Motor Capacitor Products.

Is R1234yf a fluorine refrigerant substitute?

The 1234yf refrigerant manufacturer has been tested and the European Union has determined that R1234yf, a substitute for R134a jointly developed by Honeywell and DuPont, is safe and can be produced and sold in Europe. But Mercedes-Benz did not think so. They stated that R1234yf may produce substances harmful to the human body during the combustion process. For fear of pollution to the environment, refrigerants that were widely used in cars before are banned from being used in Europe. But Mercedes-Benz refused to implement this decision, which also led to the introduction of a short-term policy prohibiting the sale of Mercedes-Benz models in France. Mercedes-Benz also stated that it can use carbon dioxide in the air-conditioning system to replace R1234yf promoted by the European Union. HFO-1234yf can be applied to refrigerator refrigerant, fire extinguishing agent, heat transfer medium, propellant, foaming agent, foaming agent, gas medium, sterilant carrier, polymer monomer, particle removal fluid, carrier gas fluid, Grinding polishing agent, replacement desiccant, electric cycle working fluid and other fields. Alternatives to fluorine refrigerants As a global hot topic, alternatives to fluorine refrigerants require an ozone depletion potential (ODP) of O, a low greenhouse effect potential (GWP), and the shortest possible atmospheric lifetime. The first-generation refrigerant, chlorofluorocarbon dichlorodifluoromethane (CCl2F2, CFC-12), etc., has been eliminated due to ODP at around 1. Hydrochlorofluorocarbon monochlorodifluoromethane (CHClF2, HCFC-22), etc., as a first- and second-generation transitional refrigerant replacement, has an ODP>0 and is gradually being phased out. The second-generation refrigerant, hydrofluorocarbon 1,1,1,2-tetrafluoroethane (CF3CH2F, HFC-134a), is widely used in automobile air conditioners, home appliances and industrial and commercial refrigeration equipment, and can also be used in foaming, fire extinguishing, gas Sol and cleaning industries. However, HFC-134a has a relatively high greenhouse effect (GWPu003d1300), a long atmospheric lifetime, and a large amount of use will cause global warming, and it has also entered the countdown stage. In the future, which refrigerant will become a substitute for HFC-134a? 1,1-difluoroethane (CH3CHF2, HFC-152a), natural working fluid CO2 (R744) and 2,3,3,3-tetrafluoroethane Propylene (CF3CFu003dCH2, HFO-1234yf) has become a hot topic now. Among them, HF0-1234yf can be applied to refrigerator refrigerant, fire extinguishing agent, heat transfer medium, propellant, foaming agent, foaming agent, gas medium, sterilant carrier, polymer monomer, particle removal fluid, carrier gas fluid , Grinding polishing agent, replacement desiccant, electric cycle working fluid and other fields.

start capacitor suppliers air conditioner capacitor is liked by everyone and is used in every household.

Our vision serves as the framework for our refrigerant gas and guides every aspect of our business by describing what we need to accomplish in order to continue achieving sustainable, quality growth.

In terms of air conditioner capacitor, why is it different than other production? How does it fit a true need or desire for your requires? Is it simple to use? Make life easier?

The value you get from watching how Hangzhou E cool refrigeration Co.,Ltd operates and runs our company and the potential mentorship you would get from us will go a long way towards helping customers understand our company.

In the boundless Chinese market, there are a number of enterprises that provides start capacitor suppliers refrigerant gas of their own brand over the years, but few have won more support from customers on the international stage than Arkool.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect