loading

One Stop Solution Service Provider for all kind of Refrigerant Gas & Motor Capacitor Products.

Interpretation: Industrial chiller refrigerant cycle system

When the chiller refrigerant cycle system, the liquid refrigerant in the evaporator absorbs heat from the water and starts to evaporate. A certain temperature difference is formed between the final refrigerant and the water, and the liquid refrigerant is completely evaporated and becomes gaseous and then compressed The machine sucks and compresses. The gaseous refrigerant absorbs heat through the condenser and condenses into liquid. After being throttled by the thermal expansion valve, it becomes a low-temperature and low-pressure refrigerant and enters the evaporator to complete the refrigerant cycle process.

When    cold water machine molding products, due to the variety of raw materials, the size and shape of the molded product, the required clamping force is also different, please adjust the mold according to the actual need of z* low mold clamping力调。 Strength adjustment. In this way, power consumption can be saved and the service life of the machine can be significantly extended.

  Industrial chillers must pay attention to the safety of the operation when using the machine. Please check the safety devices of the machine, the safety of the ejector rod and the reliability of the safety door at the beginning of each operation. When the machine is running, remember not to put your hands into the clamping mechanism. When taking products, the safety door must be opened, and the safety door can only be closed after confirming the safety of personnel and no foreign objects in the mold. In addition, the hand cannot reach between the nozzle and the mold gate during operation. When repairing the mold, turn off the oil pump motor.

   screw chiller has the advantages of high efficiency, good performance, low noise, low vibration, energy saving, high reliability and long life. According to customer needs and the size of the cold tonnage, a single machine or a combination of multiple machines is used. The compressor can automatically rotate alternately according to load changes, balance the operating hours of each compressor, and greatly extend the service life of the chiller.

Hangzhou E cool refrigeration Co.,Ltd specializes in undertaking corporate offers to cater the needs of different companies.

Hangzhou E cool refrigeration Co.,Ltd is one of leading start capacitor suppliers refrigerant gas distributors. You can order , and accessories for your need. Meeting your business need is always our top priority. Any of your enquiry is warmly welcomed.

Through our distribution and marketing competencies, Hangzhou E cool refrigeration Co.,Ltd provides creative, customized, solutions for our customers. As a result, we achieve superior profit growth as the air conditioner capacitor company of choice.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect