Insufficient refrigerant is a serious harm to the refrigeration system

For the chiller refrigerant.com/hfc-refrigerant' target='_blank'>refrigeration system, as long as it is installed correctly and there is no leakage at the pipe connection, the system can operate effectively for a long time. Do not add refrigerant. But if there is a refrigerant leak in the chiller, we should first try to find the leak, then solve the leak, and finally replenish the refrigerant. So how should we judge that the refrigerant is insufficiently charged? What is the harm to the chiller refrigeration system when it is insufficient?

1. Reasons for insufficient refrigerant   

1. The newly installed chiller is not charged with refrigerant as required.  

2. The air tightness of the system is not good, causing refrigerant leakage.  

3. Improper operation and maintenance, causing refrigerant leakage, etc.

Second, the impact of insufficient refrigerant charge on the chiller

1. If the compressor suction pressure and discharge pressure Will be lower than the normal value, then you need to check whether it is due to insufficient refrigerant charge.  

2. In the case of insufficient refrigerant charge, the compressor will run under no rated load, resulting in light load or even idling of the chiller. At this time, the current is lower than the rated current.  

3. Insufficient refrigerant charge will also reduce the evaporation capacity in the evaporator, so that the cooling capacity will decrease and the cooling effect of the unit will be poor, and the room temperature or storage temperature will drop slowly or not.  

4. If you see that the thermal expansion valve of the chiller is not frosting, it is rarely frosted. When there is no condensation, little or no condensate in the air conditioner, it may also be caused by insufficient refrigerant charge.

5. If you see that the evaporator of the chiller unit has little or no frost, or no condensation, little or no condensate during air-conditioning conditions, the same reason is that the refrigerant is insufficiently charged .

When there is insufficient refrigerant in the chiller, we should conduct a strict and careful inspection of the entire refrigeration system to determine the specific cause or the location of the leakage, so as to eliminate the fault. And replenish the refrigerant in accordance with the regulations to restore the normal operation of the chiller.

The increasing consumption demand in key segments such as start capacitor suppliers, start capacitor suppliers and start capacitor suppliers have been driving the sales of and its derivatives worldwide.

Satisfying our customers with the appropriate level of quality is a primary goal and a fundamental element as refrigerant gas of our business mission.

air conditioner capacitor developed from Hangzhou E cool refrigeration Co.,Ltd’s unique skills in high technology has helped to produce refrigerant gasstart capacitor suppliers.

air conditioner capacitor is receiving a great positive feedback in the market. And many of our clients are fully satisfied with it.

start capacitor suppliers refrigerant gas is slower than start capacitor suppliers but has a number of special applications, such as for start capacitor suppliers.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect