Industrial cold water machine refrigerant recycling method

a refrigerant, how the industrial cold water machine back to the accumulator?

industrial cold water machine the refrigerant back into the concrete operation process of accumulator is: 1, open mechanism of industrial cold water cooling system of all valves, and counterclockwise budge suction valve to make it fully open, and then use the multi-purpose joint make repair valve with suction valve. 2, to repair the valve closed, suction stop valve will be dispatched to tee position; 3, clockwise to export cut-off valve closed accumulator; 4, industrial cold water machine the refrigeration compressor, evaporator in the main force that is drawn into the condenser and the accumulator.

(2) how to industrial cold water machine the refrigerant back into the cylinder?

refrigerant is special cylinder storage, refrigerant recovery in industrial water cooling machine, cylinder, 1, should be first in the suction valve of by-pass hole channel access to repair the valve with pressure vacuum gauge, the suction valve to the tee. 2, counterclockwise budge exhaust valve to fully open conditions, unscrew the exhaust valve bypass hole plug, fitted with a multi-purpose joint. 3, use the hose will be empty of refrigerant inside the cylinder cohesion on the multi-purpose joint of exhaust valve, but do not tighten the joint cohesion refrigerant cylinders. 4, slightly opened the exhaust valve, after cleaning of air inside the connecting hose, tight joint. 5, completely opened the refrigerant cylinder valves, and cooling water shower refrigerant cylinders. 6, air compressor, clockwise slowly closed exhaust valve, refrigerant within the industrial cold water machine is gradually to the refrigerant pressure inside the cylinder.

industrial cold water machine the refrigerant whether back to the accumulator is the cylinder, only refrigerant recovery of completed, then the suction pressure gauge is 0. 01 mpa, in a closed compressor running after, if the pressure has not risen suggests that refrigerant back end, if the pressure is rising, suggests that refrigerant did not draw back the clean, shall, in accordance with the above method operation again.

this release of the refrigerant, freon manufacturers, for details, please click on the query.

In the past few decades, start capacitor suppliers production has increased because of the use of refrigerant gas.

To receive more professional tips and super quality products for start capacitor suppliers, go to our website Arkool Refrigeration to place your order. Do not wait any longer.

So, what's a manufacturer to do? Familiarize ourselves with producing air conditioner capacitor in various technologies.

Digging into our roots and acknowledging out heritage can be fruitful on both a high-quality and professional level of refrigerant gas.

In various different types of start capacitor suppliers, start capacitor suppliers air conditioner capacitor is one of the most commonly used.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect