If it is found that how to deal with R22 refrigerant leak

it is not hard to find in daily life of refrigerant leakage, R22 refrigerant leakage if what should I do? Believe that this is a lot of problems in the use of R22 refrigerant friends, small make up for everyone to do a detailed introduction about this issue, let's learn together.

R22 refrigerant low toxicity of this product, but with its preparation of tetrafluoroethylene cracking gas and residual liquid ingredients in some high toxic class, can cause acute poisoning.

after the poisoning light person has a cough, chest tightness, dizziness, fatigue, nausea, etc. Animal experiments showed that an anesthetic effect R22 refrigerant and heart toxicity. So what is the R22 refrigerant leakage emergency treatment? Human exposure R22 refrigerant which first aid measures should be taken?

R22 refrigerant leakage emergency handling methods:

according to the influence of gas zoning alert, irrelevant personnel evacuation from the lateral wind, the wind. Recommended emergency response personnel Dai Zheng pressure self-contained breathing apparatus, in general work overalls. Prohibit contact or across the leakage. Cut off the leak source as possible. Spray water vapor flow or change steam cloud, avoid the leakage water contact. A direct hit water leakage or leakage source is prohibited. To prevent the gas through the sewers, ventilation system and spatial diffusion in sealing. Gas leakage allow discharged into the atmosphere. Keep ventilation leakage places.

human exposure R22 refrigerant which first aid measures should be taken:

skin contact: remove contaminated clothing and immediately flush with plenty of liquid water 20 ~ 30 minutes. If you have any discomfort, medical treatment; Eye contact: immediately filed a eyelid, with plenty of liquid water or saline flushing 10 ~ 15 minutes. If you have any discomfort, medical treatment;

inhalation: quickly from the scene to fresh air. Keep respiratory tract unobstructed. Such as difficulty in breathing, give oxygen. Stop breathing, heartbeat, cardiopulmonary resuscitation immediately. Go to a doctor;

eating: not contact through this way.

more about each of the refrigerant R22 over here, hope to be able to bring you some help, if you have a demand on refrigerant R22, welcome consultation discussion with us, we wholeheartedly at your service.

need huge investment, so it is important to shop with caution.

Hangzhou E cool refrigeration Co.,Ltd’s mission is to be the leading global innovator, developer and provider of air conditioner capacitor start capacitor suppliers products, systems, and services.

Hangzhou E cool refrigeration Co.,Ltd's refrigerant gas are sturdy, easy to operate, friendly work machines that deliver high-quality start capacitor suppliers for start capacitor suppliers purposes.

With wide range of [分类关键词] products of top quality in offer, Hangzhou E cool refrigeration Co.,Ltd will definitely be your best option for air conditioner capacitor solution. Do feel free to contact us at Arkool Refrigeration.

Hangzhou E cool refrigeration Co.,Ltd expects to reach the desired profits in the first year and does not anticipate serious cash flow problems.

GET IN TOUCH WITH Us
recommended articles
knowledge NEWS CENTER NEWS
With the signing of the Montreal Agreement in 1987, CFC refrigerants (such as R-11, R-12, etc.) have been completely banned due to their strong damaging effects on atmospheric ozone.
  Refrigeration network: The design of each air conditioner has the problem of how to determine the refrigerant charge, especially in the air conditioner that uses capillary tubes as throttling devices, because the capillary tubes have a higher regulating capacity The expansion valve is poor, and the change of the charge has a greater impact on its performance.
  【】Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south.
As we all know, the power density of equipment in the computer room is high, so the volume heat is high.
  The air source heat pump is in winter heating conditions.
  【】Semiconductor cooling fins, also called thermoelectric cooling fins, are cooling devices composed of semiconductors.
   R22 and R410, which are commonly used in air conditioning and refrigeration, are two different refrigerants.
  【】In practical applications, some of the following methods are often used to detect whether the refrigerant in the refrigeration system is sufficient.
no data
 12-1501 Yangguangcheng, Lvting Road, Yuhang District, Hangzhou, Zhejiang Province, China
Icetop refrigeration
Mobile: +86 18668096671
E-Mail: ecm@ecmrefrigerant.com
Whatsapp/Wechat:
+8618668096671
Wechat: +8618668096671
QQ: 435672887
Mobile: +8613429676071
E-Mail: cool@ecmrefrigerant.com
Whatsapp/Wechat:
+8613429676071
no data
Copyright © 2025 Hangzhou Icetop refrigeration Co.,Ltd  /  Oasis Chemical Co.,Limited / A-COOL MANUFACTURING CO.,LIMITED  | Sitemap
Customer service
detect